The influence of a liner on deep bulk-fill restorations: Randomized clinical trial
| dc.contributor.author | Torres, Carlos Rocha Gomes [UNESP] | |
| dc.contributor.author | Mailart, Mariane Cintra [UNESP] | |
| dc.contributor.author | Rocha, Rafael Santos [UNESP] | |
| dc.contributor.author | Sellan, Pablo Lenin Benitez [UNESP] | |
| dc.contributor.author | Contreras, Sheila Célia Mondragón [UNESP] | |
| dc.contributor.author | Di Nicoló, Rebeca [UNESP] | |
| dc.contributor.author | Borges, Alessandra Bühler [UNESP] | |
| dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
| dc.date.accessioned | 2021-06-25T10:34:37Z | |
| dc.date.available | 2021-06-25T10:34:37Z | |
| dc.date.issued | 2020-11-01 | |
| dc.description.abstract | Objective: The aim of this study was to evaluate the influence of a liner on the clinical performance of deep posterior restorations performed with bulk-fill composite. Methods: 30 subjects received two restorations on deep preparations in posterior teeth, without pulpal exposure, after selective carious-tissue removal in one-stage. The internal walls reached the inner quarter of dentin, but with a radiographically detectable zone of firm dentin remaining. The pulpal protection using a layer of glass ionomer composite liner (Ionoseal, Voco) was applied in just one preparation. The adhesive system Futurabond U (Voco) was applied in all preparations, which were restored with the bulk-fill pure Ormocer nanohybrid composite (Admira Fusion Xtra - Voco), in up to 4 mm thick increments. All restorations were evaluated using the FDI criteria after 7 days, 6, 12 and 24 months postoperatively. Results: After 24-months, 25 patients attended the recall and 50 restorations were evaluated. The Fisher's statistical analysis (5%) showed no difference between the techniques for the esthetic, functional and biological properties. No postoperative sensitivity was reported for both groups. Conclusion: The application of a liner did not influence the clinical performance of deep restorations with bulk-fill Ormocer composite. Clinical relevance: The application of a liner with a GIC-based material did not have a significant effect on the clinical performance of bulk-fill restorations and seems to be unnecessary for the material tested. | en |
| dc.description.affiliation | Sao Paulo State University - UNESP Institute of Science and Technology Department of Restorative Dentistry, São José Dos Campos, Avenida Engenheiro Francisco José Longo, 777, Jardim São Dimas | |
| dc.description.affiliationUnesp | Sao Paulo State University - UNESP Institute of Science and Technology Department of Restorative Dentistry, São José Dos Campos, Avenida Engenheiro Francisco José Longo, 777, Jardim São Dimas | |
| dc.identifier | http://dx.doi.org/10.1016/j.jdent.2020.103454 | |
| dc.identifier.citation | Journal of Dentistry, v. 102. | |
| dc.identifier.doi | 10.1016/j.jdent.2020.103454 | |
| dc.identifier.issn | 0300-5712 | |
| dc.identifier.scopus | 2-s2.0-85091679996 | |
| dc.identifier.uri | http://hdl.handle.net/11449/206576 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Journal of Dentistry | |
| dc.source | Scopus | |
| dc.subject | Bulk-fill | |
| dc.subject | Glass ionomer cement | |
| dc.subject | Liner | |
| dc.subject | Ormocer | |
| dc.subject | Pulp Protection | |
| dc.title | The influence of a liner on deep bulk-fill restorations: Randomized clinical trial | en |
| dc.type | Artigo | |
| dspace.entity.type | Publication | |
| unesp.author.orcid | 0000-0002-9485-5514[1] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
| unesp.department | Odontologia Restauradora - ICT | pt |