Publicação: EFFECT of GAMMA IRRADIATION on CAPROLACTAM MIGRATION FROM MULTILAYER POLYAMIDE 6 FILMS INTO WATER FOOD SIMULANT and VALIDATION of THE METHOD
dc.contributor.author | Felix, J. S. | |
dc.contributor.author | Manzoli, J. E. | |
dc.contributor.author | Padula, M. | |
dc.contributor.author | Monteiro, Magali [UNESP] | |
dc.contributor.institution | Univ Zaragoza | |
dc.contributor.institution | Instituto de Pesquisas Energéticas e Nucleares (IPEN) | |
dc.contributor.institution | Universidade São Judas Tadeu (USJT) | |
dc.contributor.institution | Packaging Technol Ctr ITAL CETEA | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:23:40Z | |
dc.date.available | 2014-05-20T13:23:40Z | |
dc.date.issued | 2011-01-01 | |
dc.description.abstract | A gas chromatographic method to determine caprolactam migration from non-irradiated and irradiated multilayer polyamide 6 films into water food simulant was developed and validated. Linear range was 0.96 to 642.82 mu g/mL, with correlation coefficient of 0.9999. Limit of detection and quantification was 0.32 and 0.96 mu g/mL, respectively. Method precision showed RSD values lower than 2.1%, while method accuracy showed recovery from 89 to 105%. Caprolactam levels reduced with the increase of radiation dose for films used for meat foodstuffs, while for films used as cheese packaging only slight differences occurred. | en |
dc.description.affiliation | Univ Zaragoza, Dept Analyt Chem, I3A, CPS, Zaragoza, Spain | |
dc.description.affiliation | Nucl & Energet Res Inst IPEN CTR, São Paulo, Brazil | |
dc.description.affiliation | Universidade São Judas Tadeu (USJT), São Paulo, Brazil | |
dc.description.affiliation | Packaging Technol Ctr ITAL CETEA, Inst Food Technol, Campinas, SP, Brazil | |
dc.description.affiliation | São Paulo State Univ UNESP, Sch Pharmaceut Sci, Dept Food & Nutr, Araraquara, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Sch Pharmaceut Sci, Dept Food & Nutr, Araraquara, Brazil | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Programa de Apoio ao Desenvolvimento Científico da Faculdade de Ciências Farmacêuticas da UNESP (PADC) | |
dc.format.extent | 46-50 | |
dc.identifier | http://connection.ebscohost.com/c/articles/87765901/effect-gamma-irradiation-caprolactam-migration-from-multilayer-polyamide-6-films-water-food-simulant-validation-method | |
dc.identifier.citation | Italian Journal of Food Science. Pinerolo: Chiriotti Editori, v. 23, p. 46-50, 2011. | |
dc.identifier.issn | 1120-1770 | |
dc.identifier.uri | http://hdl.handle.net/11449/7177 | |
dc.identifier.wos | WOS:000208717100012 | |
dc.language.iso | eng | |
dc.publisher | Chiriotti Editori | |
dc.relation.ispartof | Italian Journal of Food Science | |
dc.relation.ispartofjcr | 0.615 | |
dc.relation.ispartofsjr | 0,268 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | caprolactam | en |
dc.subject | migration | en |
dc.subject | multilayer polyamide 6 films | en |
dc.subject | gamma irradiation | en |
dc.subject | validation of analytical method | en |
dc.title | EFFECT of GAMMA IRRADIATION on CAPROLACTAM MIGRATION FROM MULTILAYER POLYAMIDE 6 FILMS INTO WATER FOOD SIMULANT and VALIDATION of THE METHOD | en |
dc.type | Artigo | |
dcterms.rightsHolder | Chiriotti Editori | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquara | pt |
unesp.department | Alimentos e Nutrição - FCF | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: