Logotipo do repositório
 

Publicação:
A device to improve the Schleger and Turner method for sweating rate measurements

dc.contributor.authorFranco Pereira, Alfredo Manuel
dc.contributor.authorAlves, Alexandre
dc.contributor.authorInfante, Paulo
dc.contributor.authorTitto, Evaldo A. L.
dc.contributor.authorBaccari Júnior, Flávio [UNESP]
dc.contributor.authorAlmeida, J. A. Afonso
dc.contributor.institutionUniv Evora
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:32:31Z
dc.date.available2014-05-20T15:32:31Z
dc.date.issued2010-01-01
dc.description.abstractThe objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.en
dc.description.affiliationUniv Evora, Inst Ciencias Agr Mediterran, Dept Zootecnia, P-7000554 Evora, Portugal
dc.description.affiliationUniv Evora, Dept Matemat, P-7000554 Evora, Portugal
dc.description.affiliationUniv São Paulo, FZEA, São Paulo, Brazil
dc.description.affiliationUNESP, Botucatu, SP, Brazil
dc.description.affiliationUnespUNESP, Botucatu, SP, Brazil
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT)
dc.description.sponsorshipICAM (Evora, Portugal).
dc.format.extent37-43
dc.identifierhttp://dx.doi.org/10.1007/s00484-009-0250-3
dc.identifier.citationInternational Journal of Biometeorology. New York: Springer, v. 54, n. 1, p. 37-43, 2010.
dc.identifier.doi10.1007/s00484-009-0250-3
dc.identifier.issn0020-7128
dc.identifier.urihttp://hdl.handle.net/11449/41400
dc.identifier.wosWOS:000273746000005
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofInternational Journal of Biometeorology
dc.relation.ispartofjcr2.577
dc.relation.ispartofsjr0,897
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectSweating rateen
dc.subjectEvaporative thermolysisen
dc.subjectCattleen
dc.titleA device to improve the Schleger and Turner method for sweating rate measurementsen
dc.typeArtigo
dcterms.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dcterms.rightsHolderSpringer
dspace.entity.typePublication
unesp.author.orcid0000-0001-9430-9399[1]
unesp.author.orcid0000-0002-4300-9561[4]
unesp.author.orcid0000-0002-1644-9502[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
unesp.departmentMelhoramento e Nutrição Animal - FMVZpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: