Logotipo do repositório

Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images

dc.contributor.authorMauad, Leticia Queiroz
dc.contributor.authorTeixeira Doriguetto, Paulo Victor
dc.contributor.authorAlmeida, Daniela de
dc.contributor.authorCastilho Fardim, Karolina Aparecida [UNESP]
dc.contributor.authorMachado, Alessiana Helena
dc.contributor.authorDevito, Karina Lopes
dc.contributor.institutionUniv Fed Juiz de Fora
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2021-06-25T12:38:29Z
dc.date.available2021-06-25T12:38:29Z
dc.date.issued2021-01-01
dc.description.abstractObjectives: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. Methods: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. Results: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. Conclusions: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.en
dc.description.affiliationUniv Fed Juiz de Fora, Sch Dent, Grad Program Dent, Juiz De Fora, MG, Brazil
dc.description.affiliationSao Paulo State Univ, Sch Dent, Inst Sci & Technol, Dept Oral Diag & Surg, Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUniv Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, Brazil
dc.description.affiliationUniv Fed Juiz de Fora, Sch Dent, Dept Dent Clin, Juiz De Fora, MG, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Sch Dent, Inst Sci & Technol, Dept Oral Diag & Surg, Sao Jose Dos Campos, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdCAPES: 001
dc.format.extent7
dc.identifierhttp://dx.doi.org/10.1259/dmfr.20200134
dc.identifier.citationDentomaxillofacial Radiology. London: British Inst Radiology, v. 50, n. 3, 7 p., 2021.
dc.identifier.dimensionspub.1130901110
dc.identifier.doi10.1259/dmfr.20200134
dc.identifier.issn0250-832X
dc.identifier.issn1476-542X
dc.identifier.orcid0000-0001-9429-0085
dc.identifier.orcid0000-0001-5045-2679
dc.identifier.orcid0000-0001-6001-4103
dc.identifier.orcid0000-0001-5037-5466
dc.identifier.orcid0000-0003-1048-1859
dc.identifier.pmcidPMC7923067
dc.identifier.pmid32941742
dc.identifier.urihttp://hdl.handle.net/11449/210062
dc.identifier.wosWOS:000621319000001
dc.language.isoeng
dc.publisherBritish Inst Radiology
dc.publisherOxford University Press (OUP)
dc.relation.ispartofDentomaxillofacial Radiology
dc.sourceWeb of Science
dc.sourceDimensions
dc.subjectcone beam computed tomography
dc.subjectartefacts
dc.subjectceramics
dc.subjectmetal ceramic alloys
dc.subjectdental marginal adaptation
dc.titleQuantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT imagesen
dc.typeArtigopt
dcterms.rightsHolderBritish Inst Radiology
dspace.entity.typePublication
relation.isOrgUnitOfPublicationc73b286a-b5fa-4312-a7ec-62f987e7b514
relation.isOrgUnitOfPublication.latestForDiscoveryc73b286a-b5fa-4312-a7ec-62f987e7b514
unesp.author.orcid0000-0001-6001-4103[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentDiagnóstico e Cirurgia - ICTpt

Arquivos