Publicação: Effects of thermocycling on mechanical properties of soft lining materials.
dc.contributor.author | Goiato, Marcelo Coelho [UNESP] | |
dc.contributor.author | Zucolotti, Bruna Carolina Rossatti | |
dc.contributor.author | Santos, Daniela Micheline dos [UNESP] | |
dc.contributor.author | Moreno, Amália | |
dc.contributor.author | Rezende, Maria Cristina Rosifini Alves [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:24:32Z | |
dc.date.available | 2014-05-27T11:24:32Z | |
dc.date.issued | 2009-12-01 | |
dc.description.abstract | Soft linings are materials used to reduce the tension and forces of mastication, forming all or part of the fitting surface of a denture. This study evaluated the effect of thermocycling on water absorption, solubility, Shore A hardness and color stability of permanent soft liner materials. MATERIAL AND METHODS: Two chemically activated soft liner materials (Sofreliner S; GC Reline Ultrasoft) were tested. Twenty cylindrical specimens (30.0 x 1.0 mm) were prepared for measuring water absorption and solubility and another twenty (30.0 x 3 mm) for analyzing Shore A hardness and color stability. Color was measured by a spectrophotometer before and after 2000 thermocycles. A one-way ANOVA test and Tukey test at a 5% confidence level (p<0.05) were performed. RESULTS: The results did not show statistical differences for water absorption, solubility or color stability. The post-thermocycling Shore A hardness values were significantly higher than those before the treatment. CONCLUSION: Thermocycling of soft liner materials increased Shore A hardness. | en |
dc.format.extent | 227-232 | |
dc.identifier | http://www.actaodontologicalat.com/archivo/v22n3/fulltext/articulo11.pdf | |
dc.identifier.citation | Acta odontológica latinoamericana : AOL, v. 22, n. 3, p. 227-232, 2009. | |
dc.identifier.issn | 0326-4815 | |
dc.identifier.lattes | 9719883814872582 | |
dc.identifier.orcid | 0000-0002-1327-9667 | |
dc.identifier.orcid | 0000-0002-3800-3050 | |
dc.identifier.scopus | 2-s2.0-77953039492 | |
dc.identifier.uri | http://hdl.handle.net/11449/71419 | |
dc.language.iso | eng | |
dc.relation.ispartof | Acta Odontológica Latinoamericana (AOL) | |
dc.relation.ispartofsjr | 0,264 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Scopus | |
dc.subject | denture | |
dc.subject | materials testing | |
dc.subject | mechanics | |
dc.subject | temperature | |
dc.subject | Denture Liners | |
dc.subject | Materials Testing | |
dc.subject | Mechanics | |
dc.subject | Temperature | |
dc.title | Effects of thermocycling on mechanical properties of soft lining materials. | en |
dc.type | Artigo | pt |
dcterms.license | http://www.actaodontologicalat.com/peditorial.html | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 9719883814872582 | |
unesp.author.orcid | 0000-0002-3800-3050[1] | |
unesp.author.orcid | 0000-0002-1327-9667[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |