Publicação: A Randomized Clinical Trial of Oral Health-Related Quality of Life, Peri-Implant and Kinesiograph Parameters in Wearers of One-or Two-Implant Mandibular Overdentures
dc.contributor.author | Policastro, Vivian Barnabé | |
dc.contributor.author | Paleari, André Gustavo | |
dc.contributor.author | Leite, Andressa Rosa Perin | |
dc.contributor.author | Mendoza-Marin, Danny Omar | |
dc.contributor.author | Cassiano, Ana Flávia Balestrero | |
dc.contributor.author | Shaddox, Luciana Machion | |
dc.contributor.author | Compagnoni, Marco Antonio | |
dc.contributor.author | Pero, Ana Carolina | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-12-11T17:24:05Z | |
dc.date.available | 2018-12-11T17:24:05Z | |
dc.date.issued | 2018-01-01 | |
dc.description.abstract | Purpose: The present randomized clinical trial compared the oral health-related quality of life (OHRQoL), peri-implant parameters, mandible movements, and maxillary complete denture movement during chewing between wearers of single- (1-IOD) and wearers of two-implant overdentures (2-IODs) for a period of 12 months. Materials and Methods: Twenty-one complete denture wearers were randomly allocated into two parallel groups: 1-IOD (n = 11) or 2-IODs (n = 10). The validated Brazilian version of the OHIP-EDENT was used to evaluate the OHRQoL. A kinesiograph recorded maxillary complete denture movement during chewing of hard food testing (polysulphide impression material) and soft food testing (bread). Peri-implant parameters were also recorded: plaque index (PI), bleeding on probing (BOP), and probing depth (PD). The Friedman test was used to compare the OHRQoL data and peri-implant parameters among periods; the Mann-Whitney test was performed to compare the groups (1- and 2-IODs). One-way ANOVA and the Bonferroni test were used to compare mandible movement during chewing among periods, and the t-test for independent samples was used to compare the groups. Maxillary complete denture movement was analyzed using three-way ANOVA followed by the Bonferroni test. All statistical analyses were performed at α = 0.05. Results: Both treatments led to better general OHRQoL in comparison to conventional complete dentures (p < 0.001). Better OHRQoL was observed among 2-IOD patients at the 12-month follow up (p = 0.034). Peri-implant parameters were similar irrespective of the group and follow-up period. Vertical opening was significantly higher among 1-IOD patients at 3 months (p = 0.038). Decreased maxillary denture vertical intrusions were observed with complete dentures in comparison with overdentures (p = 0.006), regardless of the food test (p = 0.251); however, vertical intrusion was significantly higher among 1-IOD patients (p = 0.043). Conclusions: This study suggested that 1-IOD can improve patient OHRQoL and may be similar to 2-IODs in preservation of both peri-implant parameters and masticatory movements. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP Univ Estadual Paulista Araraquara Brazil | |
dc.description.affiliation | Department of Restorative Dentistry, Alfenas Dental School Federal University of Alfenas Brazil | |
dc.description.affiliation | Department of Periodontology, College of Dentistry University of Florida Gainesville, FL | |
dc.identifier | http://dx.doi.org/10.1111/jopr.12796 | |
dc.identifier.citation | Journal of Prosthodontics. | |
dc.identifier.doi | 10.1111/jopr.12796 | |
dc.identifier.issn | 1532-849X | |
dc.identifier.issn | 1059-941X | |
dc.identifier.lattes | 8921196002764597 | |
dc.identifier.scopus | 2-s2.0-85045751456 | |
dc.identifier.uri | http://hdl.handle.net/11449/177120 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Prosthodontics | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Complete denture | |
dc.subject | Implant | |
dc.subject | Kinesiograph | |
dc.subject | Mandibular overdenture | |
dc.subject | Mastication quality of life | |
dc.title | A Randomized Clinical Trial of Oral Health-Related Quality of Life, Peri-Implant and Kinesiograph Parameters in Wearers of One-or Two-Implant Mandibular Overdentures | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isDepartmentOfPublication.latestForDiscovery | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.lattes | 2999722781960616[8] | |
unesp.author.lattes | 8921196002764597 | |
unesp.author.orcid | 0000-0002-0203-2386[8] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |