Logotipo do repositório
 

Publicação:
Photoelastic Stress Analysis in Screwed and Cemented Implant-Supported Dentures With External Hexagon Implants

dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorTonella, Bianca Piccolotto
dc.contributor.authorFerraco, Renato
dc.contributor.authorFalcon-Antenucci, Rosse Mary
dc.contributor.authorPerri de Carvalho, Paulo Sergio [UNESP]
dc.contributor.authorRosifini Alves-Rezende, Maria Cristina [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:07Z
dc.date.accessioned2014-05-20T13:43:11Z
dc.date.available2013-09-30T18:30:07Z
dc.date.available2014-05-20T13:43:11Z
dc.date.issued2010-07-01
dc.description.abstractThe aim of this study was to assess the stress distribution of the retention systems (screwed and cemented) for implant-supported fixed partial dentures by means of photoelastic method. Two models were made of photoelastic resin PL-2 with 2 implants (phi = 4.00 x 10 mm) located in the second premolar and molar region in each photoelastic model, varying the retention system (screwed and cemented). The implant-supported fixed partial dentures were standardized and made of Ni-Cr alloy. Axial and oblique (45 degrees) forces of 100 N were applied on the occlusal surface by means of a Universal Testing Machine (EMIC-DL 3000; Sao Jose dos Pinhais, Parana, Brazil). The results were observed and photographed in the field of a circular polariscope and qualitatively analyzed with the aid of computer software (Adobe Photoshop, San Jose, CA). The screw retention system presented the highest number of fringes when the loads were applied on the premolar, pontic, and molar and showed this behavior in all load applications, under axial and oblique loads. It was concluded that there was a better stress distribution and lower magnitude of stress on the cemented implant-supported dentures, under axial and oblique loads. Oblique load caused an increase in stress concentrations in all the models.en
dc.description.affiliationSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Surg & Integrated Clin, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Surg & Integrated Clin, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConexao Sistemas de Protese
dc.description.sponsorshipIdFAPESP: 07/55061-3
dc.format.extent1110-1113
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181e1b46e
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 4, p. 1110-1113, 2010.
dc.identifier.doi10.1097/SCS.0b013e3181e1b46e
dc.identifier.issn1049-2275
dc.identifier.lattes5581364193525500
dc.identifier.urihttp://hdl.handle.net/11449/15037
dc.identifier.wosWOS:000280149100038
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectDental implanten
dc.subjectfixed partial denturesen
dc.subjectphotoelastic stress analysisen
dc.subjectscrew retaineden
dc.subjectcement retaineden
dc.titlePhotoelastic Stress Analysis in Screwed and Cemented Implant-Supported Dentures With External Hexagon Implantsen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5581364193525500
unesp.author.orcid0000-0002-6184-0981[4]
unesp.author.orcid0000-0003-0670-5004[1]
unesp.author.orcid0000-0002-1327-9667[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentCirurgia e Clínica Integrada - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: