Logotipo do repositório
 

Publicação:
Cyclic fatigue resistance of heat-treated nickel-titanium instruments

dc.contributor.authorTanomaru-Filho, Mário [UNESP]
dc.contributor.authorEspir, Camila Galletti [UNESP]
dc.contributor.authorVenção, Ana Carolina [UNESP]
dc.contributor.authorMacedo-Serrano, Nathaly [UNESP]
dc.contributor.authorCamilo-Pinto, Jader [UNESP]
dc.contributor.authorGuerreiro-Tanomaru, Juliane Maria [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:27:23Z
dc.date.available2022-04-29T08:27:23Z
dc.date.issued2018-06-01
dc.description.abstractIntroduction: This study compared the cyclic fatigue resistance (CFR) of new instruments manufactured by heat-treated nickel-titanium wire. Methods and Materials: Ninety-six new instruments from HyFlex CM (HF), Edge File (EF), Pro Design S (PDS/L) and Mtwo (MT) (20/0.06 and 25/0.06) (n=12) systems were evaluated. A stainless steel device was used and time and number of cycles to fracture (NCF) were observed. Fragments were measured and fracture surface was evaluated using scanning electron microscope (SEM). ANOVA and Tukey’s tests were applied with the level of significance set at 0.05. Results: PDS 20/0.06 and PDL 25/0.06 instruments presented the highest CFR. MT 20/0.06 and MT 25/0.06 showed the lowest CFR (P<0.05). The length of fragments was similar for 25/0.06 instruments and HF presented the highest one for 20/0.06 instruments. SEM analyses showed morphology suggestive of ductile fracture. Conclusion: Heat treatment increased resistance to cyclic fatigue differently for each type of instrument. PDS 20/0.06 and PDL 25/0.06 present higher cyclic fatigue resistance.en
dc.description.affiliationDepartment of Restorative Dentistry Araraquara School of Dentistry Univ Estadual Paulista, Rua Humaitá, 1680, Centro
dc.description.affiliationUnespDepartment of Restorative Dentistry Araraquara School of Dentistry Univ Estadual Paulista, Rua Humaitá, 1680, Centro
dc.format.extent312-317
dc.identifierhttp://dx.doi.org/10.22037/iej.v13i3.18637
dc.identifier.citationIranian Endodontic Journal, v. 13, n. 3, p. 312-317, 2018.
dc.identifier.doi10.22037/iej.v13i3.18637
dc.identifier.issn2008-2746
dc.identifier.issn1735-7497
dc.identifier.scopus2-s2.0-85049880887
dc.identifier.urihttp://hdl.handle.net/11449/228561
dc.language.isoeng
dc.relation.ispartofIranian Endodontic Journal
dc.sourceScopus
dc.subjectCyclic fatigue
dc.subjectInstrumentation
dc.subjectNickel-titanium
dc.subjectRotary system
dc.titleCyclic fatigue resistance of heat-treated nickel-titanium instrumentsen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt