Publicação: Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment
dc.contributor.author | Sundfeld, Daniel | |
dc.contributor.author | Pavani, Caio Cesar [UNESP] | |
dc.contributor.author | Schott, Timm Cornelius | |
dc.contributor.author | Machado, Lucas Silveira | |
dc.contributor.author | Pini, Núbia Inocêncya Pavesi | |
dc.contributor.author | Bertoz, André Pinheiro De Magalhães [UNESP] | |
dc.contributor.author | Sundfeld, Renato Herman [UNESP] | |
dc.contributor.institution | Ingá University Center - UNINGÁ | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Eberhard Karls University | |
dc.contributor.institution | Federal University of Rio Grande do Sul - UFRGS | |
dc.date.accessioned | 2018-12-11T17:19:35Z | |
dc.date.available | 2018-12-11T17:19:35Z | |
dc.date.issued | 2018-04-20 | |
dc.description.abstract | Objectives: The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. Methods: The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. Results: The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. Conclusions: The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Clinical significance: Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment. | en |
dc.description.affiliation | Department of Restorative Dentistry and Prosthodontics Ingá University Center - UNINGÁ, 317 PR Road | |
dc.description.affiliation | Department of Restorative Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio St | |
dc.description.affiliation | Department of Orthodontics and Orofacial Orthopedics Eberhard Karls University, Osiamderstr. 2-8 | |
dc.description.affiliation | Department of Conservative Dentistry School of Dentistry Federal University of Rio Grande do Sul - UFRGS, 110 Paulo Gama Av | |
dc.description.affiliation | Department of Pediatrics and Social Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio St | |
dc.description.affiliationUnesp | Department of Restorative Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio St | |
dc.description.affiliationUnesp | Department of Pediatrics and Social Dentistry Araçatuba Dental School São Paulo State University - UNESP, 1192 José Bonifácio St | |
dc.format.extent | 1-6 | |
dc.identifier | http://dx.doi.org/10.1007/s00784-018-2439-5 | |
dc.identifier.citation | Clinical Oral Investigations, p. 1-6. | |
dc.identifier.doi | 10.1007/s00784-018-2439-5 | |
dc.identifier.file | 2-s2.0-85045723588.pdf | |
dc.identifier.issn | 1436-3771 | |
dc.identifier.issn | 1432-6981 | |
dc.identifier.scopus | 2-s2.0-85045723588 | |
dc.identifier.uri | http://hdl.handle.net/11449/176205 | |
dc.language.iso | eng | |
dc.relation.ispartof | Clinical Oral Investigations | |
dc.relation.ispartofsjr | 0,986 | |
dc.relation.ispartofsjr | 0,986 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Scopus | |
dc.subject | Dental bleaching | |
dc.subject | Enamel microabrasion | |
dc.subject | TheraMon microsensor | |
dc.subject | Wearing-times | |
dc.title | Dental bleaching on teeth submitted to enamel microabrasion 30 years ago—a case report of patients’ compliance during bleaching treatment | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 3787326351445431[6] | |
unesp.author.orcid | 0000-0002-1746-3138[6] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Odontologia Infantil e Social - FOA | pt |
unesp.department | Odontologia Restauradora - FOA | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-85045723588.pdf
- Tamanho:
- 2.45 MB
- Formato:
- Adobe Portable Document Format
- Descrição: