Logotipo do repositório
 

Publicação:
A greener flow injection method based on a LWCC for the screening of tetracycline antibiotics in bovine milk samples

dc.contributor.authorRodríguez, Michael Pérez [UNESP]
dc.contributor.authorFerreira Da Silva, Bianca [UNESP]
dc.contributor.authorPezza, Helena Redigolo [UNESP]
dc.contributor.authorPezza, Leonardo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:28:53Z
dc.date.available2018-12-11T17:28:53Z
dc.date.issued2016-07-14
dc.description.abstractAn easy and greener flow injection method was developed for the spectrophotometric screening of tetracycline antibiotic residues in bovine milk. The combined benefits of the use of a detection system based on a liquid waveguide capillary cell (LWCC) and stop-flow (60 s) conditions significantly enhanced (45.6-fold) the analytical sensitivity. The determination is based on the formation of tetracycline azo derivatives (λmax = 435 nm) from diazotized p-sulfanilic acid, in a slightly alkaline medium. The analytical conditions were optimized by multivariate analysis, using a fractional factorial design. The linear range was 50-400 μg L-1, and the limits of detection and quantification were in the ranges 8.6-12.2 μg L-1 and 28.8-40.7 μg L-1, respectively. The applicability of the LWCC-based method was successfully tested using fortified milk samples that were only submitted to a prior acid treatment. The screening provided a quick response, enabling the determination of whether the tetracyclines were above or below the limit established by legislation (100 μg L-1). The positive samples were also analyzed by an AOAC Official Method, and the results obtained with the two methods were in good agreement. Additionally, the presence of tetracycline residues was confirmed using an HPLC-MS/MS reference analytical procedure. The excellent performance of the new screening method makes it suitable for use in the quality control of bovine milk in the food industry, aiming at consumer protection.en
dc.description.affiliationInstituto de Química Universidade Estadual Paulista Julio de Mesquita Filho UNESP, R. Prof. Francisco Degni 55
dc.description.affiliationUnespInstituto de Química Universidade Estadual Paulista Julio de Mesquita Filho UNESP, R. Prof. Francisco Degni 55
dc.format.extent5262-5271
dc.identifierhttp://dx.doi.org/10.1039/c6ay00536e
dc.identifier.citationAnalytical Methods, v. 8, n. 26, p. 5262-5271, 2016.
dc.identifier.doi10.1039/c6ay00536e
dc.identifier.issn1759-9679
dc.identifier.issn1759-9660
dc.identifier.lattes5978908591853524
dc.identifier.scopus2-s2.0-84977138840
dc.identifier.urihttp://hdl.handle.net/11449/178125
dc.language.isoeng
dc.relation.ispartofAnalytical Methods
dc.relation.ispartofsjr0,619
dc.relation.ispartofsjr0,619
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.titleA greener flow injection method based on a LWCC for the screening of tetracycline antibiotics in bovine milk samplesen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes5978908591853524
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt
unesp.departmentQuímica Orgânica - IQARpt

Arquivos