Publicação: Influence of spraying parameters on the electrochemical behaviour of HVOF thermally sprayed stainless steel coatings in 3.4% NaCl
dc.contributor.author | Guilemany, J. M. | |
dc.contributor.author | Fernandez, J. | |
dc.contributor.author | Espallargas, N. | |
dc.contributor.author | Suegama, P. H. | |
dc.contributor.author | Benedetti, Assis Vicente [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:17:56Z | |
dc.date.available | 2014-05-20T14:17:56Z | |
dc.date.issued | 2006-02-08 | |
dc.description.abstract | Stainless steel coatings obtained by High Velocity Oxygen Fuel (HVOF) were characterized using optical (OM) and scanning electron microscopy (SEM), electron probe micro-analysis, X-ray diffraction (XRD), open-circuit potential (E-OC) measurements, electrochemical impedance spectroscopy (EIS) and polarisation tests. Differences among coated steels were mainly related with the gun-substrate distance parameter (310 nm for samples A and B and 260 min for C and D). The open-circuit potential values measured for all the samples after 18 h of immersion in aerated and unstirred 3.4% NaCl solution were: - 0.334, - 0.360, - 0.379 and - 0.412 V vs. Ag/AgCl,KClsat. for samples A to D, respectively. For EIS measurements, Nyquist plots showed higher capacitive semi-circle for samples sprayed at longer distance, indicating higher corrosion resistance in NaCl solution. (c) 2005 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, UNESP, Dept Quim Fis, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, UNESP, Dept Quim Fis, BR-14801970 Araraquara, SP, Brazil | |
dc.format.extent | 3064-3072 | |
dc.identifier | http://dx.doi.org/10.1016/j.surfcoat.2005.02.116 | |
dc.identifier.citation | Surface & Coatings Technology. Lausanne: Elsevier B.V. Sa, v. 200, n. 9, p. 3064-3072, 2006. | |
dc.identifier.doi | 10.1016/j.surfcoat.2005.02.116 | |
dc.identifier.issn | 0257-8972 | |
dc.identifier.uri | http://hdl.handle.net/11449/25380 | |
dc.identifier.wos | WOS:000235254000030 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Surface & Coatings Technology | |
dc.relation.ispartofjcr | 2.906 | |
dc.relation.ispartofsjr | 0,928 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | HVOF | pt |
dc.subject | stainless steel | pt |
dc.subject | thermal spraying | pt |
dc.subject | corrosion | pt |
dc.subject | electrochemical behaviour | pt |
dc.title | Influence of spraying parameters on the electrochemical behaviour of HVOF thermally sprayed stainless steel coatings in 3.4% NaCl | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.lattes | 1769008264876945[5] | |
unesp.author.orcid | 0000-0002-0243-6639[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Físico-Química - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: