Logo do repositório

Equivalent Circuit of Piezoelectric Diaphragms for Impedance-Based Structural Health Monitoring Applications

dc.contributor.authorDe Freitas, Everaldo S. [UNESP]
dc.contributor.authorBaptista, Fabricio G. [UNESP]
dc.contributor.authorBudoya, Danilo E. [UNESP]
dc.contributor.authorDe Castro, Bruno A. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUnilins-University Center of Lins
dc.date.accessioned2018-12-11T17:13:21Z
dc.date.available2018-12-11T17:13:21Z
dc.date.issued2017-09-01
dc.description.abstractPiezoelectric diaphragms are low-cost acoustic components commonly used in a wide variety of electronic devices, where the typical function is to generate an audible alarm. However, scientific study concerning the use of these components in advanced applications has increased in recent years because of their low cost and widespread availability in several standard sizes. Based on a growing interest in these components, we propose a basic equivalent electromechanical circuit considering a 1-D vibration assumption of piezoelectric diaphragms for structural health monitoring applications based on the electromechanical impedance (EMI) technique, which was used in this paper to assess the sensitivity of piezoelectric diaphragms to structural damage. The proposed circuit is a three-port type and is suitable for small metal structures. The sensitivities of three diaphragms of different sizes to structural damage were assessed using the proposed equivalent circuit and compared with the sensitivity of a conventional transducer commonly used in the EMI method. In addition, tests were performed on aluminum bars to experimentally validate the equivalent circuit, and the theoretical and experimental results correspond well.en
dc.description.affiliationDepartment of Electrical Engineering Laboratory of Transducers and Data Acquisition School of Engineering Bauru São Paulo State University (UNESP)
dc.description.affiliationDepartment of Electrical Engineering and Automation Unilins-University Center of Lins
dc.description.affiliationUnespDepartment of Electrical Engineering Laboratory of Transducers and Data Acquisition School of Engineering Bauru São Paulo State University (UNESP)
dc.format.extent5537-5546
dc.identifierhttp://dx.doi.org/10.1109/JSEN.2017.2725946
dc.identifier.citationIEEE Sensors Journal, v. 17, n. 17, p. 5537-5546, 2017.
dc.identifier.doi10.1109/JSEN.2017.2725946
dc.identifier.file2-s2.0-85023609997.pdf
dc.identifier.issn1530-437X
dc.identifier.scopus2-s2.0-85023609997
dc.identifier.urihttp://hdl.handle.net/11449/174899
dc.language.isoeng
dc.relation.ispartofIEEE Sensors Journal
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectdiaphragm
dc.subjectequivalent circuit
dc.subjectimpedance
dc.subjectPiezoelectric
dc.subjectSHM
dc.titleEquivalent Circuit of Piezoelectric Diaphragms for Impedance-Based Structural Health Monitoring Applicationsen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication4c2e649a-dc0d-49ec-bc7f-f5f46e998cd2
relation.isDepartmentOfPublication.latestForDiscovery4c2e649a-dc0d-49ec-bc7f-f5f46e998cd2
unesp.author.orcid0000-0001-5939-9448[1]
unesp.author.orcid0000-0002-1200-4354[2]
unesp.author.orcid0000-0002-6278-8740[3]
unesp.author.orcid0000-0003-4581-1459[4]
unesp.departmentEngenharia Elétrica - FEBpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-85023609997.pdf
Tamanho:
3.19 MB
Formato:
Adobe Portable Document Format
Descrição: