Logotipo do repositório
 

Publicação:
Laboratory testes with quality data in Dentistry

dc.contributor.authorCampos, Juliana Alvares Duarte Bonini [UNESP]
dc.contributor.authorOliveira, Ana Luísa Botta Martins de
dc.contributor.authorSantos, Patrícia Aleixo do
dc.contributor.authorOliveira, Ana Carolina Botta Martins de
dc.contributor.authorGarcia, Patrícia Petromilli Nordi Sasso [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Juiz de Fora (UFJF)
dc.contributor.institutionCentro Universitário de Araraquara (UNIARA)
dc.contributor.institutionStony Brook University
dc.date.accessioned2015-08-06T16:13:43Z
dc.date.available2015-08-06T16:13:43Z
dc.date.issued2013
dc.description.abstractIn laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.en
dc.description.affiliationUniversidade Federal de Juiz de Fora, Departamento de Odontologia Social e Infantil
dc.description.affiliationCentro Universitário de Araraquara, Departamento de Odontologia
dc.description.affiliationStony Brook University, Department of General Dentistry
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Odontologia Social, Faculdade de Odontologia de Araraquara
dc.format.extent288-297
dc.identifierhttp://www.portaldeperiodicos.unisul.br/index.php/JR_Dentistry/article/view/1706
dc.identifier.citationJournal of Research in Dentistry, v. 1, n. 4, p. 288-297, 2013.
dc.identifier.fileISSN2317-5907-2013-01-04-288-297.pdf
dc.identifier.issn2317-5907
dc.identifier.lattes1307608053028698
dc.identifier.lattes3856214417891959
dc.identifier.lattes0718519731550644
dc.identifier.orcid0000-0003-4607-5975
dc.identifier.urihttp://hdl.handle.net/11449/126013
dc.language.isoeng
dc.relation.ispartofJournal of Research in Dentistry
dc.rights.accessRightsAcesso aberto
dc.sourceCurrículo Lattes
dc.subjectReproducibility of resultsen
dc.subjectLaboratory researchen
dc.subjectDentistryen
dc.titleLaboratory testes with quality data in Dentistryen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes1307608053028698
unesp.author.lattes3856214417891959
unesp.author.lattes0718519731550644[5]
unesp.author.orcid0000-0003-4607-5975[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Social - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ISSN2317-5907-2013-01-04-288-297.pdf
Tamanho:
714.07 KB
Formato:
Adobe Portable Document Format