Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces

dc.contributor.authorCorrea, Cassia Bellotto [UNESP]
dc.contributor.authorPires, Juliana Rico [UNESP]
dc.contributor.authorFernandes-Filho, Romeu Belon [UNESP]
dc.contributor.authorSartori, Rafael [UNESP]
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:33:07Z
dc.date.accessioned2014-05-20T13:45:17Z
dc.date.available2013-09-30T18:33:07Z
dc.date.available2014-05-20T13:45:17Z
dc.date.issued2009-07-01
dc.description.abstractPurpose: The influence of fatigue and the fluoride ion corrosion process on Streptococcus mutans adherence to commercially pure Titanium (Cp Ti) implant/component set surfaces were studied.Materials and Methods: Thirty Nobel implants and 30 Neodent implants were used. Each commercial brand was divided into three groups. Group A: control, Group B: sets submitted to fatigue (105 cycles, 15 Hz, 150 N), and Group C: sets submitted to fluoride (1500 ppm, pH 5.5) and fatigue, simulating a mean use of 5 years in the oral medium. Afterward, the sets were contaminated with standard strains of S. mutans (NTCC 1023) and analyzed by scanning electronic microscopy (SEM) and colony-forming unit counts (CFU/mL).Results: By SEM, bacterial adherence was verified only in group C in both brands. By CFU/mL counts, S. mutans was statistically higher in both brands in group C than in groups A and B (p < 0.05, ANOVA).Conclusion: The process of corrosion by fluoride ions on Cp Ti implant/component sets allowed greater S. mutans adherence than in the absence of corrosion and with the fatigue process in isolation.en
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthodont, UNESP, BR-14800000 Araraquara, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Periodontol, UNESP, BR-14800000 Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthodont, UNESP, BR-14800000 Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Periodontol, UNESP, BR-14800000 Araraquara, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipSão Paulo, State of São Paulo
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdFAPESP: 04/09621-9
dc.description.sponsorshipIdFAPESP: 05/03166-0
dc.format.extent382-387
dc.identifierhttp://dx.doi.org/10.1111/j.1532-849X.2009.00463.x
dc.identifier.citationJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Malden: Wiley-blackwell, v. 18, n. 5, p. 382-387, 2009.
dc.identifier.doi10.1111/j.1532-849X.2009.00463.x
dc.identifier.issn1059-941X
dc.identifier.lattes8547747556446020
dc.identifier.urihttp://hdl.handle.net/11449/15919
dc.identifier.wosWOS:000207914500003
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry
dc.relation.ispartofjcr1.745
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectFluorideen
dc.subjectcorrosionen
dc.subjectdental implantsen
dc.subjectbacterial adhesionen
dc.titleFatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfacesen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes8547747556446020
unesp.author.orcid0000-0003-0916-1962[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: