Publicação: Histologic and biomechanical evaluation of 2 resorbable-blasting media implant surfaces at early implantation times
dc.contributor.author | Marin, Charles | |
dc.contributor.author | Bonfante, Estevam A. | |
dc.contributor.author | Jeong, Ryan | |
dc.contributor.author | Granato, Rodrigo | |
dc.contributor.author | Giro, Gabriela [UNESP] | |
dc.contributor.author | Suzuki, Marcelo | |
dc.contributor.author | Heitz, Claiton | |
dc.contributor.author | Coelho, Paulo G. | |
dc.contributor.institution | School of Health Sciences | |
dc.contributor.institution | New York University | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Tufts University School of Dental Medicine | |
dc.contributor.institution | Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) | |
dc.contributor.institution | New York University College of Dentistry | |
dc.date.accessioned | 2014-05-27T11:30:06Z | |
dc.date.available | 2014-05-27T11:30:06Z | |
dc.date.issued | 2013-08-01 | |
dc.description.abstract | This study evaluated 3 implant surfaces in a dog model: (1) resorbable-blasting media + acid-etched (RBMa), alumina-blasting + acid-etching (AB/AE), and AB/AE + RBMa (hybrid). All of the surfaces were minimally rough, and Ca and P were present for the RBMa and hybrid surfaces. Following 2 weeks in vivo, no significant differences were observed for torque, bone-to-implant contact, and bone-area fraction occupied measurements. Newly formed woven bone was observed in proximity with all surfaces. | en |
dc.description.affiliation | Postgraduate Program in Dentistry UNIGRANRIO University School of Health Sciences, Duque de Caxias, RJ | |
dc.description.affiliation | Department of Biomaterials and Biomimetics New York University, New York, NY | |
dc.description.affiliation | Department of Oral Surgery and Diagnosis Faculdade de Odontologia de Araraquara UNESP, Araraquara, SP | |
dc.description.affiliation | Department of Prosthodontics Tufts University School of Dental Medicine, Boston, Mass | |
dc.description.affiliation | Department of Oral and Maxillofacial Surgery Pontificia Universidade Catolica Do Rio Grande Do sul, Porto Alegre, RS | |
dc.description.affiliation | Department of Periodontology and Implant Dentistry New York University College of Dentistry, New York, NY | |
dc.description.affiliationUnesp | Department of Oral Surgery and Diagnosis Faculdade de Odontologia de Araraquara UNESP, Araraquara, SP | |
dc.format.extent | 445-453 | |
dc.identifier | http://dx.doi.org/10.1563/AAID-JOI-D-10-00156 | |
dc.identifier.citation | Journal of Oral Implantology, v. 39, n. 4, p. 445-453, 2013. | |
dc.identifier.doi | 10.1563/AAID-JOI-D-10-00156 | |
dc.identifier.issn | 0160-6972 | |
dc.identifier.issn | 1548-1336 | |
dc.identifier.scopus | 2-s2.0-84883353478 | |
dc.identifier.uri | http://hdl.handle.net/11449/76171 | |
dc.identifier.wos | WOS:000323804300006 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Oral Implantology | |
dc.relation.ispartofjcr | 1.212 | |
dc.relation.ispartofsjr | 0,569 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Histology | |
dc.subject | Implant surface | |
dc.subject | In vivo | |
dc.subject | Osseointegration | |
dc.subject | Resorbable-blasting media | |
dc.subject | Torque | |
dc.subject | aluminum oxide | |
dc.subject | hydroxyapatite | |
dc.subject | animal | |
dc.subject | biodegradable implant | |
dc.subject | bone regeneration | |
dc.subject | dental acid etching | |
dc.subject | dental surgery | |
dc.subject | dog | |
dc.subject | evaluation | |
dc.subject | male | |
dc.subject | methodology | |
dc.subject | surface property | |
dc.subject | tibia | |
dc.subject | tooth implant | |
dc.subject | tooth implantation | |
dc.subject | torque | |
dc.subject | Absorbable Implants | |
dc.subject | Acid Etching, Dental | |
dc.subject | Air Abrasion, Dental | |
dc.subject | Aluminum Oxide | |
dc.subject | Animals | |
dc.subject | Dental Implantation, Endosseous | |
dc.subject | Dental Implants | |
dc.subject | Dogs | |
dc.subject | Durapatite | |
dc.subject | Male | |
dc.subject | Surface Properties | |
dc.subject | Tibia | |
dc.title | Histologic and biomechanical evaluation of 2 resorbable-blasting media implant surfaces at early implantation times | en |
dc.type | Artigo | |
dcterms.license | http://www.joionline.org/userimages/ContentEditor/1240858717108/Terms_and_Conditions_ORIM1.pdf | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-7590-8158[5] | |
unesp.author.orcid | 0000-0001-6867-8350[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Diagnóstico e Cirurgia - FOAR | pt |