Logotipo do repositório
 

Publicação:
Molecular assay optimized by Taguchi experimental design method for venous thromboembolism investigation

dc.contributor.authorCelani de Souza, Helder Jose [UNESP]
dc.contributor.authorMoyses, Cinthia B.
dc.contributor.authorPontes, Fabricio J. [UNESP]
dc.contributor.authorDuarte, Roberto N.
dc.contributor.authorSanches da Silva, Carlos Eduardo
dc.contributor.authorAlberto, Fernando Lopes
dc.contributor.authorFerreira, Ubirajara R. [UNESP]
dc.contributor.authorSilva, Messias Borges [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFleury Diagnost
dc.contributor.institutionCentro Federal de Educação Tecnológica (CEFET)
dc.contributor.institutionUniversidade Federal de Itajubá (UNIFEI)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:28:31Z
dc.date.available2014-05-20T13:28:31Z
dc.date.issued2011-10-01
dc.description.abstractTwo mutations - Factor V Leiden (1691G > A) and the 20210G > A on the Prothrombin gene - are key risk factors for a frequent and potentially fatal disorder called Venous Thromboembolism. These molecular alterations can be investigated using real-time Polymerase Chain Reaction (PCR) with Fluorescence Resonance Energy Transfer (FRET) probes and distinct DNA pools for both factors. The objective of this paper is to present an application of Taguchi Experimental Design Method to determine the best parameters adjustment of a Molecular Assays Process in order to obtain the best diagnostic result for Venous Thromboembolism investigation. The complete process contains six three-level factors which usually demands 729 experiments to obtain the final result, if using a Full Factorial Array. In this research, a Taguchi L27 Orthogonal Array is chosen to optimize the analysis and reduce the number of experiments to 27 without degrading the final result accuracy. The application of this method can lessen the time and cost necessary to achieve the best operation condition for a required performance. The results is proven in practice and confirmed that the Taguchi method can really offer a good approach for clinical assay efficiency and effectiveness improvement even though the clinical diagnostics can be based on the use of qualitative techniques. (C) 2011 Elsevier Ltd. All rights reserved.en
dc.description.affiliationSão Paulo State Univ, UNESP, Dept Prod Engn, BR-12516410 Guaratingueta, SP, Brazil
dc.description.affiliationFleury Diagnost, Dept Innovat Res & Dev, São Paulo, Brazil
dc.description.affiliationCEFET, Dept Automat, Sao Joao da Boa Vista, SP, Brazil
dc.description.affiliationUniversidade Federal de Itajubá (UNIFEI), Dept Prod Engn, Itajuba, MG, Brazil
dc.description.affiliationUniv São Paulo, USP, BR-05508 São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Dept Prod Engn, BR-12516410 Guaratingueta, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdCAPES: PE024/2008
dc.format.extent231-237
dc.identifierhttp://dx.doi.org/10.1016/j.mcp.2011.08.001
dc.identifier.citationMolecular and Cellular Probes. London: Academic Press Ltd- Elsevier B.V. Ltd, v. 25, n. 5-6, p. 231-237, 2011.
dc.identifier.doi10.1016/j.mcp.2011.08.001
dc.identifier.issn0890-8508
dc.identifier.lattes9507655803234261
dc.identifier.urihttp://hdl.handle.net/11449/9500
dc.identifier.wosWOS:000297180600007
dc.language.isoeng
dc.publisherAcademic Press Ltd Elsevier B.V. Ltd
dc.relation.ispartofMolecular and Cellular Probes
dc.relation.ispartofjcr1.689
dc.relation.ispartofsjr0,617
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectTaguchien
dc.subjectDesign of experimentsen
dc.subjectReal-time PCRen
dc.subjectFRETen
dc.subjectGenotypingen
dc.titleMolecular assay optimized by Taguchi experimental design method for venous thromboembolism investigationen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderAcademic Press Ltd- Elsevier B.V. Ltd
dspace.entity.typePublication
unesp.author.lattes9507655803234261
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Guaratinguetápt
unesp.departmentProdução - FEGpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: