Publicação:
Distribuição da energia no interior de uma estufa plástica no período inverno

dc.contributor.authorKlar, Antonio Evaldo [UNESP]
dc.contributor.authorJadoski Jr., Cleber [UNESP]
dc.contributor.authorMaggi, Marcio Furlan [UNESP]
dc.contributor.authorRamiro, Juliana [UNESP]
dc.contributor.authordos Santos, Alexandre Barreto Almeida [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:21:50Z
dc.date.available2014-05-27T11:21:50Z
dc.date.issued2006-04-01
dc.description.abstractThis work aimed to study the energy distribution in protected environment during the winter of 2005. A plastic tunnel (27.5 m long, 7.5 m wide, 3.2 m high in the center and 2.00 m high in both lateral sides) was covered with polyethylene 100 micra and black shadow screen (sombrite) in lateral sides at the FCA/UNESP, Botucatu - SP. 142 minievaporimeters (500 ml volume and 147 cm2 area) were evenly distributed and set up at three heights: 0.40 m; 0.80 m and 1.20 m from soil surface in order to analyze energy distribution along the studied area. The greenhouse longitudinal axis was northwest/southeast, based on true north. Geosatistics principles and the GS+ Program were adopted to compare variables. From obtained results, it was concluded that there were significant evaporation variations at different points anf heights; the highest values were the ones closest to the soil surface (0.40m) in July and at highest heights (0.80 and 1.20m). Highest evaporations occurred in the southeastern side of the greenhouse.en
dc.description.affiliationFaculdade de Ciências Agronômicas de Botucatu Universidade Estadual Paulista, Botucatu, SP
dc.description.affiliationUnespFaculdade de Ciências Agronômicas de Botucatu Universidade Estadual Paulista, Botucatu, SP
dc.format.extent257-265
dc.identifierhttp://200.145.140.50/ojs1/viewarticle.php?id=38&layout=abstract
dc.identifier.citationIrriga, v. 11, n. 2, p. 257-265, 2006.
dc.identifier.file2-s2.0-65449178497.pdf
dc.identifier.issn1413-7895
dc.identifier.issn1808-3765
dc.identifier.scopus2-s2.0-65449178497
dc.identifier.urihttp://hdl.handle.net/11449/68812
dc.language.isopor
dc.relation.ispartofIrriga
dc.relation.ispartofsjr0,283
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectGeostatistics
dc.subjectGreenhouse position
dc.subjectMicroevaporimeters
dc.titleDistribuição da energia no interior de uma estufa plástica no período invernopt
dc.title.alternativeEnergy distribution in a plastic tunnel in winter perioden
dc.typeArtigo
dcterms.licensehttp://irriga.fca.unesp.br/index.php/irriga/about
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Agronômicas, Botucatupt
unesp.departmentEngenharia Rural - FCApt