Publicação: Accuracy assessment of a photogrammetric close-range reconstruction system
dc.contributor.author | Tommaselli, AMG | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T15:29:03Z | |
dc.date.available | 2014-05-20T15:29:03Z | |
dc.date.issued | 1998-01-01 | |
dc.description.abstract | Geometric accuracy of a close-range photogrammetric system is assessed in this paper considering surface reconstruction with structured light as its main purpose. The system is based on an off-the-shelf digital camera and a pattern projector. The mathematical model for reconstruction is based on the parametric equation of the projected straight line combined with collinearity equations. A sequential approach for system calibration was developed and is presented. Results obtained from real data are also presented and discussed. Experiments with real data using a prototype have indicated 0.5mm of accuracy in height determination and 0.2mm in the XY plane considering an application where the object was 1630mm distant from the camera. | en |
dc.description.affiliation | São Paulo State Univ, BR-19060900 President Prudente, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, BR-19060900 President Prudente, SP, Brazil | |
dc.format.extent | 46-53 | |
dc.identifier | http://dx.doi.org/10.1109/SIBGRA.1998.722732 | |
dc.identifier.citation | Sibgrapi '98 - International Symposium on Computer Graphics, Image Processing, and Vision, Proceedings. Los Alamitos: IEEE Computer Soc, p. 46-53, 1998. | |
dc.identifier.doi | 10.1109/SIBGRA.1998.722732 | |
dc.identifier.uri | http://hdl.handle.net/11449/38731 | |
dc.identifier.wos | WOS:000076805000008 | |
dc.language.iso | eng | |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE), Computer Soc | |
dc.relation.ispartof | Sibgrapi '98 - International Symposium on Computer Graphics, Image Processing, and Vision, Proceedings | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | reconstruction | pt |
dc.subject | calibration | pt |
dc.subject | close-range photogrammetry | pt |
dc.title | Accuracy assessment of a photogrammetric close-range reconstruction system | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dcterms.rightsHolder | IEEE Computer Soc | |
dspace.entity.type | Publication | |
unesp.author.lattes | 5493428631948910[1] | |
unesp.author.orcid | 0000-0003-0483-1103[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Ciências e Tecnologia, Presidente Prudente | pt |
unesp.department | Estatística - FCT | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: