Logotipo do repositório
 

Publicação:
Avaliação da confiabilidade da análise de espaço na dentadura mista utilizando modelos digitais e softwares gratuito e comercial

dc.contributor.advisorPinto, Ary dos Santos [UNESP]
dc.contributor.authorSilva, Paula Cristina Henriques da [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2021-07-20T14:47:55Z
dc.date.available2021-07-20T14:47:55Z
dc.date.issued2021-06-11
dc.description.abstractO objetivo deste estudo foi avaliar a confiabilidade da análise de espaço na dentadura mista utilizando modelos digitais e dois softwares de análise, sendo um gratuito e outro comercial, bem como a reprodutibilidade das medidas realizadas. Foram selecionadas documentação ortodônticas de 100 crianças com idade entre 7 e 10 anos, atendidas na Faculdade de Odontologia de Araraquara. Os modelos de estudo destas documentações foram digitalizados e analisados com as ferramentas do software gratuito 3D Viewer – 3 Shape e do software comercial VistaDent 3D - Dentsply. As medidas foram primeiramente realizadas no software gratuito por dois examinadores (um estudante de graduação em odontologia e um especialista em ortodontia), posteriormente o ortodontista realizou as mesmas medidas no software comercial. Os dados foram analisados estatisticamente através do software estatístico Jamovi, considerando nível de significância de 5%. O Coeficiente de Consistência Interna (Alfa de Cronbach) foi utilizado para verificar a confiabilidade das medidas e o teste t pareado foi utilizado para verificar se houve diferenças significativas. A diferença média entre as medidas obtidas nos dois softwares, pelo mesmo examinador, variou de 0,01 a 0,2 mm, o coeficiente Alfa de Cronbach foi  0,91. Entre os examinadores, o coeficiente Alfa foi  0,90, exceto para as medidas LM_43 e 36_33 (0,76 e 0,85, respectivamente), a diferença média interexaminadores foi  0,83 mm. Os dois softwares analisados são altamente confiáveis, as diferenças significativas encontradas para algumas medidas (até 0,2mm) não foi clinicamente relevante e pode ser desconsiderada. As medidas obtidas no software livre mostraram alto grau de reprodutibilidade interexaminador, independentemente do grau de qualificação do examinador.pt
dc.description.abstractThe aim of this study was to evaluate the reliability of space analysis in mixed dentition using digital models and two analysis software, free and commercial, as well as the reproducibility of the measurements performed. Orthodontic documentations of 100 children aged between 7 and 10 years, attended at the Faculty of Dentistry of Araraquara, were selected. The study models of these documentations were digitized and analyzed with the tools of the free software 3D Viewer – 3 Shape and the commercial software VistaDent 3D - Dentsply. The measurements were first collected in 3D Viewer by two examiners (dental student and orthodontic specialist). Later, the orthodontic specialist performed the same analysis of space in VistaDent 3D. Data was statistically analyzed using the Jamovi statistical software, considering a significance level of 5%. The Internal Consistency Coefficient (Cronbach's Alpha) was used to verify the reliability of the measurements and the paired t-test was used to verify if there were significant differences. The mean difference between the measurements obtained in the two software, by the same examiner, ranged from 0.01 to 0.2 mm, the Cronbach's alpha coefficient was ³ 0.91. Among the examiners, the coefficient alpha was greater than 0.90 except for 27-midline and 19-22 (respectively 0.76 and 0.85), mean difference inter-examiners were less than 0.83 mm. The two analyzed software are highly reliable, the significant difference found for some measurements (up to 0.3mm) was not clinically relevant and could be disregarded. The measurements obtained in the free software showed a high degree of inter-examiner reproducibility, regardless of the examiner's experience.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdCAPES: 001
dc.identifier.capes33004030010P2
dc.identifier.urihttp://hdl.handle.net/11449/213490
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.subjectOrtodontiapt
dc.subjectDentição mistapt
dc.subjectOdontopediatriapt
dc.subjectReprodutibilidade dos testespt
dc.subjectOrthodonticsen
dc.subjectMixed dentitionen
dc.subjectPediatric dentistryen
dc.subjectReproducibility of resultsen
dc.titleAvaliação da confiabilidade da análise de espaço na dentadura mista utilizando modelos digitais e softwares gratuito e comercialpt
dc.title.alternativeReliability assessment of space analysis in mixed dentures using digital models and free and commercial softwareen
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.embargo24 meses após a data da defesapt
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramCiências Odontológicas - FOARpt
unesp.knowledgeAreaOrtodontiapt
unesp.researchAreaNão constapt

Arquivos

Pacote Original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
silva_pch_me_arafo.par.pdf
Tamanho:
290.42 KB
Formato:
Adobe Portable Document Format
Descrição:
Carregando...
Imagem de Miniatura
Nome:
silva_pch_me_arafo.int.pdf
Tamanho:
1.59 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
3.03 KB
Formato:
Item-specific license agreed upon to submission
Descrição: