dc.date.issued2011-08-01
dc.description.abstractThe mechanical performance of cemented or screw-retained implant-supported crowns with an internal or external configuration is yet to be understood. This in vitro study evaluated the effect of screw-retained and cement-retained prostheses on internal and external implant-abutment connections. Thereby, the reliability and failure modes of crowns were investigated. Eighty-four implants (Emfils; Colosso Evolution system) were divided into four groups (n = 21 each): screw-retained and internal connection (Si), screw-retained and external connection (Se), cement-retained and internal connection (Ci), and cement-retained and external connection (Ce). Ti-6Al-4V abutments were torqued (30 Ncm) to the implants, and maxillary central incisor metal crowns were torqued (30 Ncm) or cemented (Rely X Unicem; 3M-ESPE) and subjected to accelerated life-testing in water. Use-level probability Weibull curves and reliability for 50,000 cycles at 150 N were calculated. The beta values for Si (1.72), Se (1.50), Ci (1.34), and Ce (1.77) groups indicated that fatigue/damage accumulation accelerated their failure. The Ci group presented the highest reliability, the Se group presented the lowest reliability, and Si and Ce groups presented intermediate reliability. Screw-retained restorations presented mainly abutment fracture. Cement-retained restorations resulted in failures of the screw in the Ce group, but implant/screw fracture in the Ci group.en
dc.description.affiliationUNIGRANRIO Univ, Postgrad Program Dent, Sch Hlth Sci, BR-25071202 Rio de Janeiro, Brazil
dc.description.affiliationNYU, Coll Dent, Dept Biomat & Biomimet, New York, NY USA
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthodont, Aracatuba Sch Dent, São Paulo, Brazil
dc.description.affiliationNYU, Coll Dent, Dept Prosthodont, New York, NY USA
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthodont, Aracatuba Sch Dent, São Paulo, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipMarotta Dental Studio (Farmingdale, NY, USA)
dc.description.sponsorshipEmfils Ind & Com Ltda (Itu, SP, Brazil)
dc.description.sponsorshipIdCNPq: 141870/2008-7
dc.format.extent323-330
dc.identifierhttp://dx.doi.org/10.1111/j.1600-0722.2011.00837.x
dc.identifier.citationEuropean Journal of Oral Sciences. Malden: Wiley-blackwell, v. 119, n. 4, p. 323-330, 2011.
dc.identifier.doi10.1111/j.1600-0722.2011.00837.x
dc.identifier.issn0909-8836
dc.identifier.lattes3383392287039820
dc.identifier.urihttp://hdl.handle.net/11449/15279
dc.identifier.wosWOS:000292452100011
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofEuropean Journal of Oral Sciences
dc.relation.ispartofjcr1.655
dc.relation.ispartofsjr0,789
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectcement-retaineden
dc.subjectfractographyen
dc.subjectimplant-supported prosthesesen
dc.subjectreliabilityen
dc.subjectscrew-retaineden
dc.titleEffect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crownsen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes3383392287039820
unesp.author.orcid0000-0001-6867-8350[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: