Publicação: Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis
dc.contributor.author | Tribst, João Paulo Mendes [UNESP] | |
dc.contributor.author | Dal Piva, Amanda Maria de Oliveira [UNESP] | |
dc.contributor.author | Borges, Alexandre Luiz Souto [UNESP] | |
dc.contributor.author | Bottino, Marco Antonio [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2020-12-12T02:33:20Z | |
dc.date.available | 2020-12-12T02:33:20Z | |
dc.date.issued | 2020-04-25 | |
dc.description.abstract | This study evaluated the bone microstrain, displacement, and stress distribution according to the surgical technique (conventional or Socket-shield) and evaluation period (immediately after implant installation or after healing). Each condition was modeled for the finite element analysis, totaling four groups, with a morse-taper implant and a cemented prosthesis. The maximum displacement, von Mises stress, and bone microstrain yielded higher values during the immediate stage, without a difference between Socket-shield and conventional treatments. The use of the Socket-shield technique does not negatively impact the biomechanical behavior of an implant-supported prosthesis immediately after healing from the implant installation. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP) | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP) | |
dc.format.extent | 224-231 | |
dc.identifier | http://dx.doi.org/10.1080/10255842.2019.1710833 | |
dc.identifier.citation | Computer Methods in Biomechanics and Biomedical Engineering, v. 23, n. 6, p. 224-231, 2020. | |
dc.identifier.doi | 10.1080/10255842.2019.1710833 | |
dc.identifier.issn | 1476-8259 | |
dc.identifier.issn | 1025-5842 | |
dc.identifier.scopus | 2-s2.0-85077852820 | |
dc.identifier.uri | http://hdl.handle.net/11449/201469 | |
dc.language.iso | eng | |
dc.relation.ispartof | Computer Methods in Biomechanics and Biomedical Engineering | |
dc.source | Scopus | |
dc.subject | Finite element analysis | |
dc.subject | implants | |
dc.subject | prosthetic dentistry | |
dc.title | Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-5412-3546[1] | |
unesp.author.orcid | 0000-0002-3844-2053[2] | |
unesp.author.orcid | 0000-0002-5707-7565[3] | |
unesp.author.orcid | 0000-0003-0077-3161[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |