Logotipo do repositório
 

Publicação:
Aerobic fitness evaluation during walking tests identifies the maximal lactate steady state

dc.contributor.authorPuga, Guilherme Morais [UNESP]
dc.contributor.authorKokubun, Eduardo [UNESP]
dc.contributor.authorSimões, Herbert Gustavo
dc.contributor.authorNakamura, Fabio Yuzo
dc.contributor.authorCampbell, Carmen Sílvia Grubert
dc.contributor.institutionCatholic University of Brasília
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Londrina (UEL)
dc.date.accessioned2014-05-27T11:26:51Z
dc.date.available2014-05-27T11:26:51Z
dc.date.issued2012-06-21
dc.description.abstractObjective. The aim of this study was to verify the possibility of lactate minimum (LM) determination during a walking test and the validity of such LM protocol on predicting the maximal lactate steady-state (MLSS) intensity. Design. Eleven healthy subjects (24.2 ± 4.5 yr; 74.3 ± 7.7 kg; 176.9 ± 4.1 cm) performed LM tests on a treadmill, consisting of walking at 5.5 km h -1 and with 20-22% of inclination until voluntary exhaustion to induce metabolic acidosis. After 7 minutes of recovery the participants performed an incremental test starting at 7% incline with increments of 2% at each 3 minutes until exhaustion. A polynomial modeling approach (LMp) and a visual inspection (LMv) were used to identify the LM as the exercise intensity associated to the lowest [bLac] during the test. Participants also underwent to 24 constant intensity tests of 30 minutes to determine the MLSS intensity. Results. There were no differences among LMv (12.6 ± 1.7 %), LMp (13.1 ± 1.5 %), and MLSS (13.6 ± 2.1 %) and the Bland and Altman plots evidenced acceptable agreement between them. Conclusion. It was possible to identify the LM during walking tests with intensity imposed by treadmill inclination, and it seemed to be valid on identifying the exercise intensity associated to the MLSS. Copyright © 2012 Guilherme Morais Puga et al.en
dc.description.affiliationCatholic University of Brasília, 72022-900 Brasília, DF
dc.description.affiliationInstitute of Bioscience Department of Physical Education São Paulo State University, 13506-900 Rio Claro, SP
dc.description.affiliationDepartment of Physical Education State University of Londrina, 86051-990 Londrina, PR
dc.description.affiliationUnespInstitute of Bioscience Department of Physical Education São Paulo State University, 13506-900 Rio Claro, SP
dc.identifierhttp://dx.doi.org/10.1100/2012/769431
dc.identifier.citationThe Scientific World Journal, v. 2012.
dc.identifier.doi10.1100/2012/769431
dc.identifier.file2-s2.0-84862333884.pdf
dc.identifier.issn1537-744X
dc.identifier.lattes3650843918755682
dc.identifier.orcid0000-0002-9404-3444
dc.identifier.scopus2-s2.0-84862333884
dc.identifier.urihttp://hdl.handle.net/11449/73388
dc.language.isoeng
dc.relation.ispartofThe Scientific World Journal
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectlactic acid
dc.subjectlactic acid derivative
dc.subjectadult
dc.subjectexercise intensity
dc.subjectfemale
dc.subjecthuman
dc.subjecthuman experiment
dc.subjectlactate minimum
dc.subjectmale
dc.subjectmaximal lactate steady state
dc.subjectmetabolic acidosis
dc.subjectmetabolic parameters
dc.subjectnormal human
dc.subjectsteady state
dc.subjecttreadmill ergometry
dc.subjectwalking
dc.subjectaerobic metabolism
dc.subjectblood
dc.subjectreference value
dc.subjectAdult
dc.subjectAerobiosis
dc.subjectHumans
dc.subjectLactates
dc.subjectMale
dc.subjectReference Values
dc.subjectWalking
dc.titleAerobic fitness evaluation during walking tests identifies the maximal lactate steady stateen
dc.typeArtigo
dcterms.licensehttp://www.hindawi.com/journals/aaa/guidelines/
dspace.entity.typePublication
unesp.author.lattes3650843918755682
unesp.author.orcid0000-0002-9404-3444[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Rio Claropt
unesp.departmentEducação Física - IBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84862333884.pdf
Tamanho:
1.39 MB
Formato:
Adobe Portable Document Format