Publicação:
Photoelastic Analysis of Stress Distribution in Different Retention Systems for Facial Prosthesis

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorRibeiro, Paula do Prado [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorGarcia Júnior, Idelmo Rangel [UNESP]
dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorHaddad, Marcela Filie [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:15Z
dc.date.accessioned2014-05-20T13:43:12Z
dc.date.available2013-09-30T18:30:15Z
dc.date.available2014-05-20T13:43:12Z
dc.date.issued2009-05-01
dc.description.abstractThe aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Integrated Clin & Oral Surg, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Integrated Clin & Oral Surg, BR-16015050 São Paulo, Brazil
dc.format.extent757-761
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181a28a96
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 20, n. 3, p. 757-761, 2009.
dc.identifier.doi10.1097/SCS.0b013e3181a28a96
dc.identifier.issn1049-2275
dc.identifier.lattes9719883814872582
dc.identifier.lattes5581364193525500
dc.identifier.lattes8843503367647381
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/15044
dc.identifier.wosWOS:000266295400012
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectDental implantsen
dc.subjectmaxillofacial prosthesisen
dc.subjectphotoelasticityen
dc.titlePhotoelastic Analysis of Stress Distribution in Different Retention Systems for Facial Prosthesisen
dc.typeArtigo
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
unesp.author.lattes9719883814872582
unesp.author.lattes5581364193525500
unesp.author.lattes8843503367647381
unesp.author.lattes2336450644149867[5]
unesp.author.orcid0000-0002-3800-3050[1]
unesp.author.orcid0000-0003-3020-5253[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentCirurgia e Clínica Integrada - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: