Logotipo do repositório
 

Publicação:
Overvoltage analysis of transmission towers considering the influence of tower-footing impedance

dc.contributor.authorDe Araújo, Anderson Ricardo Justo [UNESP]
dc.contributor.authorDe Seixas, Claudiner Mendes [UNESP]
dc.contributor.authorKurokawa, Sérgio [UNESP]
dc.contributor.authorKordi, Behzad
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFederal Institute of São Paulo (IFSP)
dc.contributor.institutionUniversity of Manitoba
dc.date.accessioned2018-12-11T17:35:36Z
dc.date.available2018-12-11T17:35:36Z
dc.date.issued2017-11-21
dc.description.abstractLightning is one of the main causes of outages due to backflashover mechanism in power systems. In this context, the tower-footing impedance presents a key role in the overvoltages caused by this phenomenon. Tower-footing impedance is traditionally modelled as a pure resistance, which is a good approximation, at low frequencies. However, the inductance and resistance of the tower-footing impedance strongly depend on the frequency at higher frequencies of the spectrum that is covered by lightning strokes. As such, their frequency dependence must be considered for accurate calculation of transient responses. Using the Vector Fitting technique, the admittance of grounding electrode buried in soil is represented by a lumped parameter circuit. The circuit model can be connected to transient transmission line models which enables the calculation of the voltages at the cross-arms of the tower. This paper shows the influence of tower-footing impedance of vertical electrodes on the overvoltage caused by a lightning striking at the tower top. The analysis will show how the soil characteristics and geometrical parameters affect the overvoltages at a typical transmission tower.en
dc.description.affiliationDepartment of Electrical Engineering Sao Paulo State University (UNESP)
dc.description.affiliationFederal Institute of São Paulo (IFSP)
dc.description.affiliationDepartment of Electrical and Computer Engineering University of Manitoba
dc.description.affiliationUnespDepartment of Electrical Engineering Sao Paulo State University (UNESP)
dc.format.extent287-294
dc.identifierhttp://dx.doi.org/10.1109/SIPDA.2017.8116938
dc.identifier.citation2017 International Symposium on Lightning Protection, XIV SIPDA 2017, p. 287-294.
dc.identifier.doi10.1109/SIPDA.2017.8116938
dc.identifier.scopus2-s2.0-85041309909
dc.identifier.urihttp://hdl.handle.net/11449/179542
dc.language.isoeng
dc.relation.ispartof2017 International Symposium on Lightning Protection, XIV SIPDA 2017
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectbackjlashovers
dc.subjecttower-footing impedance
dc.subjecttransmission tower
dc.titleOvervoltage analysis of transmission towers considering the influence of tower-footing impedanceen
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos