Logotipo do repositório

Evaluation of the interference of metallic dental artifacts with virtual implant planning on CBCT

dc.contributor.authordos Santos, Marcos Antônio Lima
dc.contributor.authorSantos, Aline Piruna Martins
dc.contributor.authorTakeshita, Wilton Mitsunari [UNESP]
dc.contributor.authorRomito, Giuseppe Alexandre
dc.contributor.authorda Mota Santana, Lucas Alves
dc.contributor.authorSapata, Vítor Marques
dc.contributor.authorCavalcanti, Marcelo Gusmão Paraíso
dc.date.accessioned2026-04-07T20:27:10Z
dc.date.issued2025-11-07
dc.description.abstractIntroduction: The quality of cone-beam computed tomography (CBCT) images can be affected by patient factors, including metal artifacts, which may compromise diagnosis and surgical planning. Objective: To evaluate the interference of metal restoration artifacts with superimposed DICOM and STL files using automatic segmentation in CBCT planning software and compare it with image acquisition. Methods: Subjects were divided into three groups: group 0 (zero to two restorations), group 1 (three to five restorations), and group 2 (six or more restorations). DICOM files were superimposed on STL files using four fixed anatomical positions in 3D arches for standardization. Statistical analysis included Shapiro-Wilk normality, Levene, Kruskal-Wallis, Dunn's post-tests, and Mann-Whitney U Test, with a 5% significance level. Results: The mean deviation was 0.489 mm (SD ±1.353 mm). The number of restorations significantly influenced deviations in the horizontal/anterior position (p=0.009). Group 1 differed significantly from group 2, while group 0 showed no significant differences from either. Comparing occlusion and non-occlusion, Vertical/Posterior (VP) and Vertical/Anterior (VA) positions showed significant differences, with higher means for group 1. Conclusion: Metal artifacts did not affect vertical analyses in CBCT planning but caused discrepancies in horizontal DICOM-STL segmentation adjustments.
dc.description.affiliationDepartamento de Estomatologia, Faculdade de Odontologia, Universidade de São Paulo (USP) – São Paulo (SP), Brazil
dc.description.affiliationDepartamento de Diagnóstico e Cirurgia, Faculdade de Odontologia, Universidade Estadual Paulista (Unesp) – Araçatuba (SP), Brazil
dc.description.affiliationDepartamento de Odontologia, Universidade Federal de Sergipe (UFS) – Aracaju (SE), Brazil
dc.description.affiliationDepartamento de Odontologia, UniCesumar – Maringá (PR), Brazil
dc.description.affiliationUnespDepartamento de Diagnóstico e Cirurgia, Faculdade de Odontologia, Universidade Estadual Paulista (Unesp) – Araçatuba (SP), Brazil
dc.identifierhttps://app.dimensions.ai/details/publication/pub.1194811958
dc.identifier.dimensionspub.1194811958
dc.identifier.doi10.7322/abcshs.2024043.2759
dc.identifier.issn2318-4965
dc.identifier.issn2357-8114
dc.identifier.orcid0000-0002-7589-4809
dc.identifier.orcid0000-0001-5682-1498
dc.identifier.orcid0000-0001-5669-912X
dc.identifier.orcid0000-0002-2696-0830
dc.identifier.orcid0000-0001-8011-9623
dc.identifier.urihttps://hdl.handle.net/11449/320855
dc.publisherNEPAS
dc.relation.ispartofABCS Health Sciences
dc.rights.accessRightsAcesso abertopt
dc.rights.sourceRightsoa_all
dc.rights.sourceRightsgold
dc.sourceDimensions
dc.titleEvaluation of the interference of metallic dental artifacts with virtual implant planning on CBCT
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ABCS_2024043.pdf
Tamanho:
513,95 KB
Formato:
Unknown data format
Descrição:
Obtido de: Open Alex