Publicação: Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis
dc.contributor.author | Verri, Fellippo Ramos [UNESP] | |
dc.contributor.author | Souza Batista, Victor Eduardo de [UNESP] | |
dc.contributor.author | Santiago, Joel Ferreira [UNESP] | |
dc.contributor.author | Faria Almeida, Daniel Augusto de [UNESP] | |
dc.contributor.author | Pellizzer, Eduardo Piza [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-11-03T15:28:04Z | |
dc.date.available | 2015-11-03T15:28:04Z | |
dc.date.issued | 2014-12-01 | |
dc.description.abstract | The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10,12.5, 15 mm crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-Dmodels. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metalceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200 N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises'criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maxiinum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio = 30.1% and C/I 1:1 to 1 :1.5 ratio = 46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio = 30% and C/I 1:1 to 1:1.5 ratio = 51.5%). (C) 2014 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | Univ Estadual Paulista, UNESP, Dept Dent Mat &Prosthodont, BR-16015050 Sao Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, UNESP, Dept Dent Mat &Prosthodont, BR-16015050 Sao Paulo, Brazil | |
dc.format.extent | 234-240 | |
dc.identifier | http://www.sciencedirect.com/science/article/pii/S0928493114005736 | |
dc.identifier.citation | Materials Science & engineering C-materials For Biological Applications. Amsterdam: Elsevier Science Bv, v. 45, p. 234-240, 2014. | |
dc.identifier.doi | 10.1016/j.msec.2014.09.005 | |
dc.identifier.issn | 0928-4931 | |
dc.identifier.lattes | 5581364193525500 | |
dc.identifier.uri | http://hdl.handle.net/11449/129946 | |
dc.identifier.wos | WOS:000347582600032 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Materials Science &engineering C-materials For Biological Applications | |
dc.relation.ispartofjcr | 5.080 | |
dc.relation.ispartofsjr | 1,110 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | Dental implants | en |
dc.subject | Finite element analysis | en |
dc.subject | Dental prosthesis | en |
dc.subject | Implant-supported | en |
dc.subject | Biomechanics | en |
dc.title | Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis | en |
dc.type | Artigo | pt |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 5581364193525500 | |
unesp.author.orcid | 0000-0001-5688-1669[1] | |
unesp.author.orcid | 0000-0003-1735-2224[3] | |
unesp.author.orcid | 0000-0003-0246-8101[2] | |
unesp.author.orcid | 0000-0003-0670-5004[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |