Logotipo do repositório
 

Publicação:
Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis

dc.contributor.authorVerri, Fellippo Ramos [UNESP]
dc.contributor.authorSouza Batista, Victor Eduardo de [UNESP]
dc.contributor.authorSantiago, Joel Ferreira [UNESP]
dc.contributor.authorFaria Almeida, Daniel Augusto de [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-11-03T15:28:04Z
dc.date.available2015-11-03T15:28:04Z
dc.date.issued2014-12-01
dc.description.abstractThe aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10,12.5, 15 mm crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-Dmodels. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metalceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200 N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises'criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maxiinum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio = 30.1% and C/I 1:1 to 1 :1.5 ratio = 46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio = 30% and C/I 1:1 to 1:1.5 ratio = 51.5%). (C) 2014 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista, UNESP, Dept Dent Mat &Prosthodont, BR-16015050 Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Dept Dent Mat &Prosthodont, BR-16015050 Sao Paulo, Brazil
dc.format.extent234-240
dc.identifierhttp://www.sciencedirect.com/science/article/pii/S0928493114005736
dc.identifier.citationMaterials Science & engineering C-materials For Biological Applications. Amsterdam: Elsevier Science Bv, v. 45, p. 234-240, 2014.
dc.identifier.doi10.1016/j.msec.2014.09.005
dc.identifier.issn0928-4931
dc.identifier.lattes5581364193525500
dc.identifier.urihttp://hdl.handle.net/11449/129946
dc.identifier.wosWOS:000347582600032
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofMaterials Science &engineering C-materials For Biological Applications
dc.relation.ispartofjcr5.080
dc.relation.ispartofsjr1,110
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectDental implantsen
dc.subjectFinite element analysisen
dc.subjectDental prosthesisen
dc.subjectImplant-supporteden
dc.subjectBiomechanicsen
dc.titleEffect of crown-to-implant ratio on peri-implant stress: a finite element analysisen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5581364193525500
unesp.author.orcid0000-0001-5688-1669[1]
unesp.author.orcid0000-0003-1735-2224[3]
unesp.author.orcid0000-0003-0246-8101[2]
unesp.author.orcid0000-0003-0670-5004[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos