Logotipo do repositório

Study of vertical load distribution in full-scale four-story masonry building

dc.contributor.authorAndolfato, R. P. [UNESP]
dc.contributor.authorRamalho, M. A.
dc.contributor.authorCorrêa, M. R.S.
dc.contributor.authorHaach, V. G.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2018-12-11T16:37:42Z
dc.date.available2018-12-11T16:37:42Z
dc.date.issued2014-01-01
dc.description.abstractThe vertical load distribution between the walls in a masonry building is a difficult issue in structural engineering. The absence of research regarding this subject results in using simple load distribution methods by the designers. This paper presents a study of the vertical load distribution between the walls in a full-scale four-story masonry building. Ninety blocks of a four-story building were instrumented with strain gauges and their behaviors were evaluated after an external loading was applied on some slabs. The distribution of the vertical loads in this building is also evaluated using a simple theoretical design model widely used in structural design practice. Experimental results exhibited vertical load redistribution between the walls and high influence of the flexure of slabs and walls on this distribution. Comparing experimental and theoretical results, there was similarity between the experimental and numerical results inside some wall groups, although the simple design model produced divergent stress values in the presence of significant flexural effects. © 2014, American Concrete Institute.en
dc.description.affiliationUniversidade Estadual Paulista (UNESP), São Paulo
dc.description.affiliationUniversity of São Paulo's (USP), School of Engineering of São Carlos
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP), São Paulo
dc.format.extent685-691
dc.identifierhttp://dx.doi.org/10.14359/51686626
dc.identifier.citationACI Structural Journal, v. 111, n. 3, p. 685-691, 2014.
dc.identifier.dimensionspub.1067279916
dc.identifier.doi10.14359/51686626
dc.identifier.issn0889-3241
dc.identifier.issn1944-7361
dc.identifier.orcid0000-0003-3224-5945
dc.identifier.orcid0000-0002-9501-4450
dc.identifier.scopus2-s2.0-84903997683
dc.identifier.urihttp://hdl.handle.net/11449/167631
dc.language.isoeng
dc.publisherAmerican Concrete Institute
dc.relation.ispartofACI Structural Journal
dc.relation.ispartofsjr1,233
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.sourceDimensions
dc.subjectExperimental analysis
dc.subjectStructural masonry
dc.subjectTheoretical design model
dc.subjectVertical load distribution
dc.titleStudy of vertical load distribution in full-scale four-story masonry buildingen
dc.typeArtigopt
dspace.entity.typePublication

Arquivos