Determination of the minimum alveolar concentration of sevoflurane in Holstein steers
| dc.contributor.author | Santos, Paulo SP. [UNESP] | |
| dc.contributor.author | Gonzaga, Max S. | |
| dc.contributor.author | Araújo, Marcelo A. | |
| dc.contributor.author | Deschk, Mauricio | |
| dc.contributor.author | de Siqueira, Carlos E. [UNESP] | |
| dc.contributor.author | Floriano, Beatriz P. | |
| dc.contributor.author | Cancelli, Carlos HB. | |
| dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
| dc.contributor.institution | Private practitioner | |
| dc.contributor.institution | Federal University of Mato Grosso do Sul | |
| dc.contributor.institution | Federal University of Juiz de Fora | |
| dc.contributor.institution | Universidade Federal de Sergipe (UFS) | |
| dc.date.accessioned | 2025-04-29T18:50:26Z | |
| dc.date.issued | 2023-09-01 | |
| dc.description.abstract | Objective: To determine the minimum alveolar concentration (MAC) of sevoflurane in Holstein steers using electric stimulation. Study design: Prospective experimental study. Animals: A total of 15 Holstein steers aged 7.3 ± 1.2 months and weighing 121 ± 25 kg. Methods: Animals were anesthetized with sevoflurane at 8% in oxygen at 5 L minute–1 via facemask and were intubated with an orotracheal tube of a compatible size. After 15 minutes of stabilization of the initial expired concentration of sevoflurane (FE′Sevo) at 2.6%, electrical stimulation on the thoracic limb was initiated with a sequence of 2 × 10 ms followed by 2 × 3 second electrical currents of 50 V and 50 Hz, 5 seconds apart. Following each stimulus with a negative response, the FE′Sevo was decreased by 0.2% and a 15 minute interval was awaited before the next stimulus. The procedure was repeated until the first FE′Sevo value with a positive motor response was obtained. The FE′Sevo was then increased by 0.1%, followed by a new stimulus, until a negative response was obtained. The value of MAC was calculated as the arithmetic mean between the lowest FE′Sevo associated with a negative motor response and the highest FE′Sevo associated with a positive response. Results: The mean MAC for the 15 steers was 2.0 ± 0.3%, which corresponds to 2.1 ± 0.3% at sea level. Conclusions: Based on the proposed methodology, the MAC of sevoflurane for healthy Holstein steers is 2.1 ± 0.3% at sea level. Clinical relevance: This FE′Sevo value can be used to guide depth of anesthesia in steers weighing approximately 120 kg in clinical practice. | en |
| dc.description.affiliation | Department of Animal Clinic Surgery and Reproduction Faculty of Veterinary Medicine of Araçatuba São Paulo State University (UNESP), SP | |
| dc.description.affiliation | Private practitioner, SP | |
| dc.description.affiliation | Veterinary Teaching Hospital Federal University of Mato Grosso do Sul, MS | |
| dc.description.affiliation | Veterinary Teaching Hospital Federal University of Juiz de Fora, MG | |
| dc.description.affiliation | Department of Small Animal Clinic Centre of Rural Sciences Federal University of Santa Maria (UFSM), RS | |
| dc.description.affiliationUnesp | Department of Animal Clinic Surgery and Reproduction Faculty of Veterinary Medicine of Araçatuba São Paulo State University (UNESP), SP | |
| dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
| dc.description.sponsorshipId | FAPESP: 2016/00405-9 | |
| dc.format.extent | 415-420 | |
| dc.identifier | http://dx.doi.org/10.1016/j.vaa.2023.06.001 | |
| dc.identifier.citation | Veterinary Anaesthesia and Analgesia, v. 50, n. 5, p. 415-420, 2023. | |
| dc.identifier.doi | 10.1016/j.vaa.2023.06.001 | |
| dc.identifier.issn | 1467-2995 | |
| dc.identifier.issn | 1467-2987 | |
| dc.identifier.scopus | 2-s2.0-85164360302 | |
| dc.identifier.uri | https://hdl.handle.net/11449/300731 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Veterinary Anaesthesia and Analgesia | |
| dc.source | Scopus | |
| dc.subject | bovine | |
| dc.subject | inhalation anesthesia | |
| dc.subject | ruminants | |
| dc.subject | steers | |
| dc.title | Determination of the minimum alveolar concentration of sevoflurane in Holstein steers | en |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| relation.isOrgUnitOfPublication | 1f8041b8-563c-4766-90b9-4dd9c0101666 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 1f8041b8-563c-4766-90b9-4dd9c0101666 | |
| unesp.author.orcid | 0000-0002-8535-5569[1] | |
| unesp.author.orcid | 0000-0002-1383-9732[3] | |
| unesp.author.orcid | 0000-0003-3866-1886[6] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária, Araçatuba | pt |

