Logotipo do repositório
 

Publicação:
Study of the pterygoid canal (Vidian canal) through images of cone beam computer tomography

dc.contributor.authorSilveira, Marcos Paulo Motta [UNESP]
dc.contributor.authorSantana, Fernanda Fritoli Marcondes [UNESP]
dc.contributor.authorDiamantino, Pedro Jacy Santos [UNESP]
dc.contributor.authorFardim, Karolina Aparecida Castilho [UNESP]
dc.contributor.authorManhães Júnior, Luiz Roberto Coutinho
dc.contributor.authorCosta, André Luiz Ferreira
dc.contributor.authorSaavedra, Guilherme de Siqueira Ferreira Anzaloni [UNESP]
dc.contributor.authorLopes, Sérgio Lucio Pereira de Castro [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionCruzeiro do Sul University (UNICSUL)
dc.date.accessioned2020-12-12T02:13:36Z
dc.date.available2020-12-12T02:13:36Z
dc.date.issued2020-07-01
dc.description.abstractObjective: The aim of this study was to evaluate the pterygoid canal (PC) by Cone Beam Computed Tomography (CBCT), establishing its configuration and proximity with anatomical structures. Material and Methods: We evaluated 398 CBCT exams, all from a public University radiology clinic archive. Four parameters were evaluated: single or double PC, distance between PC and the inferior part of the sphenoid sinus (SS), ratio of PC and SS and the distance between the PC and the foramen rotundum. Results: It was observed that most of the PC of the sample presented simple morphology, the most frequent type of relationship between the PC and the SS on both sides was the close contact with the wall. Among the cases that there were some distances between the PC and the inferior wall of the SS, the mean of this distance did not exceed 3.20 mm, being the left side (3.03 mm) slightly closer than the right (3.20 mm). Finally, the distances between the PC and the corresponding Foramen Rotundum are presented with mean values of 5.87 mm for the right side and 6.31 mm for the left side. Conclusion: CBCT examination is of paramount importance for PC identification; once in the studied sample, the mean values found evidence the close relation between the PC and the SS.en
dc.description.affiliationUnesp – Univ estadual Paulista Institute of Science and Technology São José dos Campos Department of Dental Materials and Prosthodontics
dc.description.affiliationUnesp – Univ estadual Paulista Institute of Science and Technology São José dos Campos Department of Diagnosis and Surgery Institute of Science and Technology
dc.description.affiliationCruzeiro do Sul University (UNICSUL)
dc.description.affiliationUnespUnesp – Univ estadual Paulista Institute of Science and Technology São José dos Campos Department of Dental Materials and Prosthodontics
dc.description.affiliationUnespUnesp – Univ estadual Paulista Institute of Science and Technology São José dos Campos Department of Diagnosis and Surgery Institute of Science and Technology
dc.format.extent1-7
dc.identifierhttp://dx.doi.org/10.14295/bds.2020.v23i3.1966
dc.identifier.citationBrazilian Dental Science, v. 23, n. 3, p. 1-7, 2020.
dc.identifier.doi10.14295/bds.2020.v23i3.1966
dc.identifier.issn2178-6011
dc.identifier.scopus2-s2.0-85087373339
dc.identifier.urihttp://hdl.handle.net/11449/200694
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Science
dc.sourceScopus
dc.subjectCone beam computed tomography
dc.subjectEndonasal approach
dc.subjectVidian canal
dc.titleStudy of the pterygoid canal (Vidian canal) through images of cone beam computer tomographyen
dc.titleEstudo do canal pterigóideo (Canal vidiano) por meio de imagens de tomografia computadorizada de feixe cônicopt
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos