Logotipo do repositório
 

Publicação:
Tissue microarrays of bone marrow aspirate clot allow assessment of multiple samples

dc.contributor.authorDomeny-Duarte, Pollyanna [UNESP]
dc.contributor.authorNiero, Ligia [UNESP]
dc.contributor.authorCustodio Domingues, Maria Ap [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-10T19:55:03Z
dc.date.available2020-12-10T19:55:03Z
dc.date.issued2020-01-01
dc.description.abstractTime optimization and cost reduction without quality loss is fundamental for scientific production. The TMA technique allows large-scale analysis of paraffin-embedded and fixed tissues using non-decalcified bone marrow specimens. Cytoinclusion samples (n = 264) were selected from patients diagnosed with monoclonal gammopathy (n = 189) at Botucatu Medical School, Sao Paulo State University. Slides were cut from the TMA block and stained with H&E and immunohistochemical markers. Of the 276 fragments included in the receptor block, 45 core detachments were observed, thus 84% of the samples remained viable. The representative material allowed for adequate analysis of isolated cells, which showed nuclear, cytoplasmic and membrane staining. Thus, we verified that inclusion of bone marrow aspirate clot is a valid alternative for TMA histological and immunohistochemical analyses.en
dc.description.affiliationSao Paulo State Univ, Botucatu Med Sch, Dept Pathol, BR-18618687 Botucatu, SP, Brazil
dc.description.affiliationSao Paulo State Univ, Botucatu Med Sch, Dept Clin Med, BR-18618687 Botucatu, SP, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Botucatu Med Sch, Dept Pathol, BR-18618687 Botucatu, SP, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Botucatu Med Sch, Dept Clin Med, BR-18618687 Botucatu, SP, Brazil
dc.format.extent3
dc.identifierhttp://dx.doi.org/10.1016/j.prp.2019.152721
dc.identifier.citationPathology Research And Practice. Munich: Elsevier Gmbh, v. 216, n. 1, 3 p., 2020.
dc.identifier.doi10.1016/j.prp.2019.152721
dc.identifier.issn0344-0338
dc.identifier.urihttp://hdl.handle.net/11449/196751
dc.identifier.wosWOS:000523597200022
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofPathology Research And Practice
dc.sourceWeb of Science
dc.subjectTMA
dc.subjectBone marrow clots
dc.subjectImmunohistochemistry
dc.titleTissue microarrays of bone marrow aspirate clot allow assessment of multiple samplesen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentClínica Médica - FMBpt
unesp.departmentPatologia - FMBpt

Arquivos