Logotipo do repositório
 

Publicação:
A symmetrical Cascaded H-bridge Multilevel Inverter used as shunt active power filter for ideal and deteriorated voltage conditions

dc.contributor.authorMortezaei, Ali
dc.contributor.authorGodoy Simoes, M.
dc.contributor.authorBusarello, Tiago D. C.
dc.contributor.authorDurra, Ahmed Al
dc.contributor.authorMarafao, Fernando P. [UNESP]
dc.contributor.institutionColorado School of Mines
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.contributor.institutionPetroleum Institute
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:30:25Z
dc.date.available2018-12-11T17:30:25Z
dc.date.issued2016-11-02
dc.description.abstractThis paper discusses the use of a Cascaded H-bridge Multilevel Inverter (CHMI) as shunt active power filter (SAPF) for selective disturbing currents compensation. The main feature of the proposed approach is the use of independent DC sources, with reduced DC-link voltages, which makes such a topology an ideal candidate for medium and high power applications with increased reliability. The developed control strategy regulates independent DC-link voltages in each H-bridge cell and allows selective compensation under a variety of voltage conditions without requiring any kind of reference-frame transformation. The selective compensation strategies are based on the decompositions proposed in the Conservative Power Theory (CPT), which result in several current-related terms associated with specific load characteristics. These current components are independent from each other and are used to define different compensation strategies, which can be selective in minimizing particular effects of disturbing loads. In order to validate the possibilities and performance of the proposed control strategies, a three-phase grid with unbalanced nonlinear loading and negligible line impedance was simulated in PSIM considering ideal and deteriorated voltage conditions.en
dc.description.affiliationColorado School of Mines
dc.description.affiliationFederal University of Santa Catarina
dc.description.affiliationPetroleum Institute
dc.description.affiliationUNESP - Univ Estadual Paulista
dc.description.affiliationUnespUNESP - Univ Estadual Paulista
dc.identifierhttp://dx.doi.org/10.1109/IAS.2016.7731855
dc.identifier.citationIEEE Industry Application Society, 52nd Annual Meeting: IAS 2016.
dc.identifier.doi10.1109/IAS.2016.7731855
dc.identifier.scopus2-s2.0-85002169978
dc.identifier.urihttp://hdl.handle.net/11449/178454
dc.language.isoeng
dc.relation.ispartofIEEE Industry Application Society, 52nd Annual Meeting: IAS 2016
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectActive power filters
dc.subjectCompensation strategies
dc.subjectHarmonics
dc.subjectMultilevel inverter
dc.subjectReactive compensation
dc.subjectSelective compensation
dc.subjectUnbalance compensation
dc.titleA symmetrical Cascaded H-bridge Multilevel Inverter used as shunt active power filter for ideal and deteriorated voltage conditionsen
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, Sorocabapt
unesp.departmentEngenharia de Controle e Automação - ICTSpt

Arquivos