Logo do repositório
 

Ecocardiografia de pacientes talassêmicos sem insuficiência cardíaca em tratamento com transfusões sanguíneas e quelação

dc.contributor.authorRodrigues, Alexandre
dc.contributor.authorGuimarães-Filho, Fábio Villaça
dc.contributor.authorBraga, João Carlos Ferreira
dc.contributor.authorRodrigues, Cássia Spínola Custódio
dc.contributor.authorWaib, Paulo
dc.contributor.authorFabron-Junior, Antonio
dc.contributor.authorTan, Doralice Marvulle
dc.contributor.authorFrança, Ana Cristina C. V.
dc.contributor.authorOkoshi, Marina Politi [UNESP]
dc.contributor.authorOkoshi, Katashi [UNESP]
dc.contributor.institutionFaculdade de Medicina de Marília (FAMEMA)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:33:42Z
dc.date.available2014-05-20T13:33:42Z
dc.date.issued2013-01-01
dc.description.abstractFUNDAMENTO: Pacientes com talassemia major (TM) apresentam hemólise crônica e necessitam de transfusões sanguíneas egularmente que podem causar cardiomiopatia por sobrecarga de ferro e insuficiência cardíaca crônica. A hemocromatose é caracterizada por acúmulo excessivo de ferro nos tecidos; acometimento do coração é a principal causa de óbito em pacientes com talassemia. OBJETIVO: Avaliar as estruturas e a função cardíaca por meio de ecocardiografia com Doppler convencional e Doppler tecidual em pacientes com TM, sem evidência clínica de insuficiência cardíaca. MÉTODOS: Trata-se de estudo observacional prospectivo de 18 pacientes com TM que recebem transfusão sanguínea regularmente. Para avaliar, separadamente, os efeitos da anemia e da transfusão sanguínea, dois grupos controles pareados por gênero, idade, peso e altura foram incluídos: um com indivíduos saudáveis (Saudável, n = 18) e outro com pacientes com anemia por deficiência de ferro (Anemia, n = 18). Análise estatística foi realizada utilizando ANOVA seguida pelo teste de Tukey ou Kruskal-Wallis e teste de Dunn. RESULTADOS: As seguintes variáveis ecocardiográficas apresentaram valores significativamente mais elevados no grupo TM do que nos grupos Anemia e Saudável: índice de volume do átrio esquerdo (Saudável: 16,4 ± 6,08; Anemia: 17,9 ± 7,02; TM: 24,1 ± 8,30 cm/m); razão E/Em septal mitral (Saudável: 6,55 ± 1,60; Anemia: 6,74 ± 0,74; TM: 8,10 ± 1,31) e duração do fluxo reverso em veias pulmonares [Saudável: 74,0 (59,0-74,0); Anemia: 70,5 (67,0-74,0); TM: 111 (87,0-120) ms]. Arazão E/A mitral foi maior no grupo TM do que no grupo Anemia (Saudável: 1,80 ± 0,40; Anemia: 1,80 ± 0,24; TM: 2,03 ± 0,34). Não foram encontradas diferenças entre os grupos em variáveis estruturais do ventrículo esquerdo e em índices de função sistólica. CONCLUSÃO: A ecocardiografia com Doppler convencional e o Doppler tecidual permite que alterações na função diastólica do ventrículo esquerdo sejam identificadas em pacientes assintomáticos com talassemia major.pt
dc.description.abstractBACKGROUND: Patients with thalassemia major present chronic hemolysis and require regular blood transfusions which may cause iron overload cardiomyopathy and chronic heart failure. Hemochromatosis is characterized by excessive iron accumulation in tissues, and heart involvement is the main cause of death in patients with thalassemia. OBJECTIVE: The aim of this study was to evaluate cardiac structure and function by conventional Doppler echocardiography and tissue Doppler imaging in patients with TM and no clinical evidence of heart failure. METHODS: This is a prospective observational study including 18 patients with thalassemia major (TM) receiving regular blood transfusion. To separately evaluate anemia and blood transfusion effects, two gender, age, weight, and height-matched control groups were included: one with healthy individuals (Healthy, n=18) and one with iron deficient anemia patients (Anemia, n=18). Statistical analysis was performed using ANOVA followed by Tukey's test or Kruskal-Wallis's and Dunn's test. RESULTS: The following echocardiographic variables presented significantly higher values in TM than the Anemia and Healthy groups: left atrium volume index (Healthy: 16.4±6.08; Anemia: 17.9±7.02; TM: 24.1±8.30 cm³/m²); mitral septal E/Em ratio (Healthy: 6.55±1.60; Anemia: 6.74±0.74; TM: 8.10±1.31); and duration of reverse pulmonary vein flow [Healthy: 74.0 (59.0-74.0); Anemia: 70.5 (67.0-74.0); TM: 111 (87.0-120) ms]. The mitral E/A ratio was higher in TM than Anemia (Healthy: 1.80±0.40; Anemia: 1.80±0.24; TM: 2.03±0.34). No differences were found in left ventricular structures and systolic function indexes. CONCLUSION: Conventional Doppler echocardiography and tissue Doppler allow changes in left ventricular diastolic function to be identified in asymptomatic patients with thalassemia major.en
dc.description.affiliationFaculdade de Medicina de Marília Departamento de Clínica Médica
dc.description.affiliationUNESP Faculdade de Medicina de Botucatu Departamento de Clínica Médica
dc.description.affiliationUnespUNESP Faculdade de Medicina de Botucatu Departamento de Clínica Médica
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdCNPq: 304998/2009-5
dc.description.sponsorshipIdCNPq: 305013/2009-0
dc.format.extent75-81
dc.identifierhttp://dx.doi.org/10.1590/S0066-782X2013005000001
dc.identifier.citationArquivos Brasileiros de Cardiologia. Sociedade Brasileira de Cardiologia - SBC, v. 100, n. 1, p. 75-81, 2013.
dc.identifier.doi10.1590/S0066-782X2013005000001
dc.identifier.fileS0066-782X2013000100012.pdf
dc.identifier.issn0066-782X
dc.identifier.lattes4463138671998432
dc.identifier.lattes1590971576309420
dc.identifier.scieloS0066-782X2013000100012
dc.identifier.urihttp://hdl.handle.net/11449/11541
dc.identifier.wosWOS:000316124400017
dc.language.isopor
dc.publisherSociedade Brasileira de Cardiologia (SBC)
dc.relation.ispartofArquivos Brasileiros de Cardiologia
dc.relation.ispartofjcr1.318
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectDoppler-Ecocardiografiapt
dc.subjectTalassemia Betapt
dc.subjectTransfusão de Sanguept
dc.subjectQuelantes de Ferropt
dc.subjectFunção Ventricularpt
dc.subjectEchocardiography, Doppleren
dc.subjectbeta-Thalassemiaen
dc.subjectBlood Transfusionen
dc.subjectIron Chelating Agentsen
dc.subjectVentricular Functionen
dc.titleEcocardiografia de pacientes talassêmicos sem insuficiência cardíaca em tratamento com transfusões sanguíneas e quelaçãopt
dc.title.alternativeEchocardiography in thalassemic patients on blood transfusions and chelation without heart failureen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes4463138671998432
unesp.author.lattes1590971576309420
unesp.author.orcid0000-0003-2339-4615[5]
unesp.author.orcid0000-0001-8980-8839[10]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentClínica Médica - FMBpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0066-782X2013000100012.pdf
Tamanho:
410.47 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: