Logo do repositório

Stress distribution in lower second molar mesialization using mini-implants: a pilot study using 3D finite element analysis

dc.contributor.authorda Silva, João Maurício Ferraz [UNESP]
dc.contributor.authorLisboa, Juliana da Costa [UNESP]
dc.contributor.authorPierre, Fernanda Zapater [UNESP]
dc.contributor.authorde ARAÚJO, Rodrigo Máximo [UNESP]
dc.contributor.authorLemos, Cleidiel Aparecido Araujo
dc.contributor.authorCruz, Ronaldo Silva [UNESP]
dc.contributor.authorVerri, Fellippo Ramos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionOdontology Department
dc.date.accessioned2023-07-29T13:36:36Z
dc.date.available2023-07-29T13:36:36Z
dc.date.issued2023-01-01
dc.description.abstractObjective: to analyze the stress distribution in a 3D model that simulates second molar mesialization using two different types of mini-implants. Material and Methods: a mandible bone model was obtained by recomposing a computed tomography performed by a software program. The cortical and trabecular bone, a lower second molar, periodontal ligament, orthodontic tube, resin cement and the mini-implants were designed and modeled using the Rhinoceros 4.0 software program. The characteristics of self-drilling orthodontic mini-implants were: one with 7 mm length, 1 mm transmucosal neck section and 1.6 mm diameter and another with 5 mm length and 1.5 mm diameter. A total of 235.161 and 224.505 elements were used for the mesh. These models were inserted into the bone block and then subjected to loads of 200 cN (centinewton). The results were calculated and analyzed by the Ansys 17.0 software program for qualitative verification through displacement and maximum principal stress maps. Results: it was possible to observe that the periodontal ligament presented low displacement and stress values. However, the physiological values presented are among those capable to provide orthodontic movement, with compression and tensile area visualization staggered between 0.1 and-0.1 MPa (megapascal). Conclusion: within the limitations of the study, the mini-implants tested showed similar results where the load on the tooth allowed dental displacement (molar mesialization), with a tendency to rotate it, theoretically allowing the second molar to take the location of the first molar.en
dc.description.affiliationUniversidade Estadual Paulista “Júlio de Mesquita Filho” Instituto de Ciência e Tecnologia Departamento de Materiais Odontológicos e Prótese
dc.description.affiliationUniversidade Federal de Juiz de Fora Odontology Department
dc.description.affiliationUniversidade Estadual Paulista “Júlio de Mesquita Filho” Dentistry Science Program on the Dental Materials and Prosthodontics Department of the Dentistry School
dc.description.affiliationUniversidade Estadual Paulista “Júlio de Mesquita Filho” Dental Materials and Prosthodontics Department of the Dentistry School
dc.description.affiliationUnespUniversidade Estadual Paulista “Júlio de Mesquita Filho” Instituto de Ciência e Tecnologia Departamento de Materiais Odontológicos e Prótese
dc.description.affiliationUnespUniversidade Estadual Paulista “Júlio de Mesquita Filho” Dentistry Science Program on the Dental Materials and Prosthodontics Department of the Dentistry School
dc.description.affiliationUnespUniversidade Estadual Paulista “Júlio de Mesquita Filho” Dental Materials and Prosthodontics Department of the Dentistry School
dc.identifierhttp://dx.doi.org/10.4322/bds.2023.e3485
dc.identifier.citationBrazilian Dental Science, v. 26, n. 1, 2023.
dc.identifier.doi10.4322/bds.2023.e3485
dc.identifier.issn2178-6011
dc.identifier.scopus2-s2.0-85146152145
dc.identifier.urihttp://hdl.handle.net/11449/248178
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Science
dc.sourceScopus
dc.subjectFinite element analysis
dc.subjectFixed orthodontic appliances
dc.subjectMini dental implants
dc.subjectOrthodontic anchorage procedures
dc.subjectTooth dislocation
dc.titleStress distribution in lower second molar mesialization using mini-implants: a pilot study using 3D finite element analysisen
dc.titleDistribuição de tensões na mesialização do segundo molar inferior usando mini-implantes: um estudo piloto usando análise de elementos finitos 3Dpt
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos