Logotipo do repositório
 

Publicação:
DETERMINATION OF MERCURY IN LIVER OF MARINE TETRAPODS BY COLD VAPOR ATOMIC FLUORESCENCE SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY IN BIOLOGICAL SAMPLES: A SYSTEMATIC COMPARISON BETWEEN THE TWO TECHNIQUES

dc.contributor.authorSilva, Raiza F. da [UNESP]
dc.contributor.authorRocha, Siomara D. da
dc.contributor.authorMenegario, Amauri A. [UNESP]
dc.contributor.authorPedrobom, Jorge H. [UNESP]
dc.contributor.authorSulato, Everton T. [UNESP]
dc.contributor.authorLuko, Karen S. [UNESP]
dc.contributor.authorElias, Lucas Pellegrini [UNESP]
dc.contributor.authorOliveira, Lucia M. de Souza [UNESP]
dc.contributor.authorSargentini Junior, Ezio
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Fed Amazonas
dc.contributor.institutionInst Nacl de Pesquisas da Amazonia
dc.date.accessioned2021-06-25T12:40:57Z
dc.date.available2021-06-25T12:40:57Z
dc.date.issued2021-01-01
dc.description.abstractThis study compares the techniques cold vapour atomic fluorescence spectrometry (CV-AFS) and inductively coupled plasma mass spectrometry (ICP-MS) for the determination of Hg in biological samples (hepatic tissue from marine tetrapods). Acid digestions were performed for the samples and aliquots of them were analysed by ICP-MS and CV-AFS. To minimize the Hg memory effect in its determination by ICP-MS, gold (200 mu g L-1 in 5% v v(-1) HCl) was added to the sample digests. The detection limits were 0.02 mg kg(-1) for ICP-MS and 0.01 mg kg(-1) for CV-AFS. Accuracy was assessed by the calculation of the recovery obtained from TORT-3 (lobster hepatopancreas) certified reference material analysis. Accurate results were obtained for both CV-AFS and ICP-MS. The comparison of the results obtained for hepatic tissue with and without lyophilization showed a significant difference among them (at 95% of confidence level), evidencing losses of Hg in the lyophilization process.en
dc.description.affiliationUniv Estadual Paulista, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil
dc.description.affiliationUniv Fed Amazonas, Dept Quim, BR-69067005 Manaus, Amazonas, Brazil
dc.description.affiliationInst Nacl de Pesquisas da Amazonia, BR-69060001 Manaus, Amazonas, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil
dc.format.extent64-69
dc.identifierhttp://dx.doi.org/10.21577/0100-4042.20170675
dc.identifier.citationQuimica Nova. Sao Paulo: Soc Brasileira Quimica, v. 44, n. 1, p. 64-69, 2021.
dc.identifier.doi10.21577/0100-4042.20170675
dc.identifier.fileS0100-40422021000100064.pdf
dc.identifier.issn0100-4042
dc.identifier.scieloS0100-40422021000100064
dc.identifier.urihttp://hdl.handle.net/11449/210144
dc.identifier.wosWOS:000631171400009
dc.language.isopor
dc.publisherSoc Brasileira Quimica
dc.relation.ispartofQuimica Nova
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectMercury
dc.subjectMarine Tetrapod
dc.subjectHg Memory Effect
dc.subjectICP-MS
dc.subjectCV-AFS
dc.titleDETERMINATION OF MERCURY IN LIVER OF MARINE TETRAPODS BY COLD VAPOR ATOMIC FLUORESCENCE SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY IN BIOLOGICAL SAMPLES: A SYSTEMATIC COMPARISON BETWEEN THE TWO TECHNIQUESen
dc.typeArtigo
dcterms.rightsHolderSoc Brasileira Quimica
dspace.entity.typePublication

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0100-40422021000100064.pdf
Tamanho:
343.57 KB
Formato:
Adobe Portable Document Format