Publicação: Cathodic stripping voltammetric determination of cefaclor in pharmaceutical formulations
dc.contributor.author | Rodrigues, LNC | |
dc.contributor.author | Fogg, A. G. | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Univ Loughborough | |
dc.date.accessioned | 2014-05-20T15:21:44Z | |
dc.date.available | 2014-05-20T15:21:44Z | |
dc.date.issued | 1999-01-01 | |
dc.description.abstract | A sensitive method is described for the determination of cefaclor by cathodic stripping voltammetry at the hanging mercury drop electrode. cefaclor is accumulated at the electrode surface as a mercury salt, which is reduced at -0.67 V. The optimum accumulation potential and accumulation time were +0.15 V and up to 180 s, respectively. Linear calibration graphs were obtained between 3.9 mu g.L-1 to 39 mu g.L-1 and the limit of determination was evaluated to be 1.9 mu g.L-1. The method was applied successfully to the determination of cefaclor in pharmaceutical formulations. | en |
dc.description.affiliation | UNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil | |
dc.description.affiliation | Univ Loughborough, Dept Chem, Loughborough LE11 3TU, Leics, England | |
dc.description.affiliationUnesp | UNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil | |
dc.format.extent | 97-109 | |
dc.identifier | http://dx.doi.org/10.1080/00032719908542601 | |
dc.identifier.citation | Analytical Letters. New York: Marcel Dekker Inc., v. 32, n. 1, p. 97-109, 1999. | |
dc.identifier.doi | 10.1080/00032719908542601 | |
dc.identifier.issn | 0003-2719 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/32855 | |
dc.identifier.wos | WOS:000078552100008 | |
dc.language.iso | eng | |
dc.publisher | Marcel Dekker Inc | |
dc.relation.ispartof | Analytical Letters | |
dc.relation.ispartofjcr | 1.206 | |
dc.relation.ispartofsjr | 0,344 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | cefaclor | pt |
dc.subject | pharmaceuticals | pt |
dc.subject | stripping voltammetry | pt |
dc.subject | hanging mercury drop | pt |
dc.title | Cathodic stripping voltammetric determination of cefaclor in pharmaceutical formulations | en |
dc.type | Artigo | |
dcterms.license | http://journalauthors.tandf.co.uk/permissions/reusingOwnWork.asp | |
dcterms.rightsHolder | Marcel Dekker Inc | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-2296-1393[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: