Logo do repositório

Test-retest reliability of knee extensors endurance test with elastic resistance

dc.contributor.authorLopes, Jaqueline Santos Silva [UNESP]
dc.contributor.authorMicheletti, Jéssica Kirsch [UNESP]
dc.contributor.authorMachado, Aryane Flauzino [UNESP]
dc.contributor.authorSouto, Larissa Rodrigues [UNESP]
dc.contributor.authorde Lima, Heloísa Paes [UNESP]
dc.contributor.authorVanderlei, Franciele Marques [UNESP]
dc.contributor.authorNetto, Jayme [UNESP]
dc.contributor.authorPastre, Carlos Marcelo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:38:26Z
dc.date.available2018-12-11T17:38:26Z
dc.date.issued2018-08-01
dc.description.abstractBackground Reliable clinical tests capable of measuring resistance are important tools for rehabilitation. One alternative that has recently increased in popularity is the use of elastic tubes, which stand out for being easy to handle, low cost, practical, and feasible. Objective Analyze the test-retest reliability of the knee extensors muscle fatigue resistance test (FRT) with elastic tubes. Methods A total of 116 healthy young males, aged between 18 and 30 years old, participated in the study. Participants performed three pre-test stages: orientation, load presentation, and familiarization with equipment, lasting two weeks. Subsequently, they performed the FRT on two occasions (test and retest), with an interval of seven days. The reliability analyzes were performed using the intraclass correlation coefficient (ICC) with 95% confidence interval and typical measurement error (TME), also expressed as coefficient of variation (CV%). Results The findings regarding the reliability of the test demonstrated satisfactory values (time: ICC = 0.66; 95%CI [0.50; 0.76]; CV(%) = 9.34; repetition: ICC = 0.61; 95%CI [0.46; 0.73], CV(%) = 13.66; rhythm: ICC = 0.52; 95%CI [0.35; 0.67], CV(%) = 10.29. Conclusion From the findings presented, it is concluded that the proposed clinical test with elastic tubes demonstrates evidence of acceptable values.en
dc.description.affiliationSão Paulo State University (Unesp) School of Technology and Sciences (Department of Physical Therapy)
dc.description.affiliationUnespSão Paulo State University (Unesp) School of Technology and Sciences (Department of Physical Therapy)
dc.identifierhttp://dx.doi.org/10.1371/journal.pone.0203259
dc.identifier.citationPLoS ONE, v. 13, n. 8, 2018.
dc.identifier.doi10.1371/journal.pone.0203259
dc.identifier.file2-s2.0-85053015322.pdf
dc.identifier.issn1932-6203
dc.identifier.scopus2-s2.0-85053015322
dc.identifier.urihttp://hdl.handle.net/11449/180166
dc.language.isoeng
dc.relation.ispartofPLoS ONE
dc.relation.ispartofsjr1,164
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.titleTest-retest reliability of knee extensors endurance test with elastic resistanceen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes2761396544058606[8]
unesp.author.orcid0000-0002-0213-6679[8]
unesp.departmentFisioterapia - FCTpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-85053015322.pdf
Tamanho:
7.45 MB
Formato:
Adobe Portable Document Format
Descrição: