Influence of Investment, Disinfection, and Storage on the Microhardness of Ocular Resins

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorGennari-Filho, Humberto [UNESP]
dc.contributor.authorZavanelli, Adriana Cristina [UNESP]
dc.contributor.authorDekon, Stefan Fiuza de Carvalho [UNESP]
dc.contributor.authorMancuso, Daniela Nardi [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:11Z
dc.date.accessioned2014-05-20T13:43:46Z
dc.date.available2013-09-30T18:30:11Z
dc.date.available2014-05-20T13:43:46Z
dc.date.issued2009-01-01
dc.description.abstractPurpose: The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin.Materials and Methods: Thirty-two test specimen investments were obtained in two silicones. A segment was cut in each test specimen, and each specimen was fixed in an acrylic disk. The specimens were then polished and submitted to the first microhardness test before immersion in distilled water and incubation for 2 months. During this 2-month period, the specimens were immersed in a water bath at 37 degrees C and were disinfected daily; half were disinfected with neutral soap and the other half were disinfected with 4% chlorhexidine gluconate. After the storage phase and disinfection, a second microhardness test was performed. The surface microhardness values for the acrylic resins were submitted to ANOVA, followed by the Tukey test.Results: The disinfection and the period of storage did not statistically influence the surface microhardness of the acrylic resin, independent of the method of investment of the specimens (Zetalabor or Vipi Sil). The investment of specimens with Zetalabor silicone presented a greater surface hardness, independent of the type of disinfection and the period of storage.Conclusions: Based on these results, we suggest that the microhardness of the resin evaluated was not influenced by the method of disinfection or the time of storage used and was affected only by the investment material.en
dc.description.affiliationUNESP São Paulo State Univ, Dept Dent Mat & Prosthodont, Sch Dent Aracatuba, BR-16050050 São Paulo, Brazil
dc.description.affiliationUnespUNESP São Paulo State Univ, Dept Dent Mat & Prosthodont, Sch Dent Aracatuba, BR-16050050 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 04/00147-2
dc.format.extent32-35
dc.identifierhttp://dx.doi.org/10.1111/j.1532-849X.2008.00372.x
dc.identifier.citationJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Malden: Wiley-blackwell, v. 18, n. 1, p. 32-35, 2009.
dc.identifier.doi10.1111/j.1532-849X.2008.00372.x
dc.identifier.issn1059-941X
dc.identifier.lattes9719883814872582
dc.identifier.lattes8942804819076392
dc.identifier.lattes3215571441204704
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.orcid0000-0003-1781-1953
dc.identifier.urihttp://hdl.handle.net/11449/15302
dc.identifier.wosWOS:000207914100007
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry
dc.relation.ispartofjcr1.745
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectAcrylic resinsen
dc.subjectfacial prosthesesen
dc.subjecthardnessen
dc.titleInfluence of Investment, Disinfection, and Storage on the Microhardness of Ocular Resinsen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes9719883814872582
unesp.author.lattes8942804819076392[4]
unesp.author.lattes3215571441204704
unesp.author.orcid0000-0002-3800-3050[1]
unesp.author.orcid0000-0003-1781-1953[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: