dc.description.abstractA new transmission line modeling - TLM is proposed based on the well-established Bergeron method. The conventional Bergeron model is characterized by the line representation through concentrated longitudinal and transversal parameters, i.e., the line electrical parameters are represented by means of electric circuit elements R, L, G and C. The novel approach of this research is the inclusion of the frequency effect in the longitudinal parameters in the Bergeron line representation. This new feature enables to extend the application of the Bergeron method for simulations of transients composed of a wide range of frequencies. (C) 2014 Elsevier B.V. All rights reserved.en
dc.description.affiliationUNESP Univ Estadual Paulista, Fac Engn Ilha Solteira, Dept Engn Eletr, Ilha Solteira, SP, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Fac Engn Ilha Solteira, Dept Engn Eletr, Ilha Solteira, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 13/00974-5
dc.format.extent14-20
dc.identifierhttp://dx.doi.org/10.1016/j.epsr.2014.07.023
dc.identifier.citationElectric Power Systems Research. Lausanne: Elsevier Science Sa, v. 117, p. 14-20, 2014.
dc.identifier.doi10.1016/j.epsr.2014.07.023
dc.identifier.issn0378-7796
dc.identifier.lattes4830845230549223
dc.identifier.urihttp://hdl.handle.net/11449/116517
dc.identifier.wosWOS:000343691200002
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofElectric Power Systems Research
dc.relation.ispartofjcr2.856
dc.relation.ispartofsjr1,048
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectBergeron line modelen
dc.subjectTransmission line modeling - TLMen
dc.subjectElectromagnetic transientsen
dc.subjectTime-domain analysisen
dc.subjectFrequency-dependent parametersen
dc.subjectPower system modelingen
dc.titleFitting the frequency-dependent parameters in the Bergeron line modelen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes4830845230549223
unesp.author.orcid0000-0002-9263-980X[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos