Logotipo do repositório
 

Publicação:
The Role of Implant/Abutment System on Torque Maintenance of Retention Screws and Vertical Misfit of Implant-Supported Crowns Before and After Mechanical Cycling

dc.contributor.authorPala Jorge, Juliana Ribeiro [UNESP]
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:10:43Z
dc.date.available2014-12-03T13:10:43Z
dc.date.issued2013-03-01
dc.description.abstractPurpose: This study aimed to evaluate the role of the implant/abutment system on torque maintenance of titanium retention screws and the vertical misfit of screw-retained implant-supported crowns before and after mechanical cycling. Materials and Methods: Three groups were studied: morse taper implants with conical abutments (MTC group), external-hexagon implants with conical abutments (EHC group), and external-hexagon implants with UCLA abutments (EHU group). Metallic crowns casted in cobalt-chromium alloy were used (n = 10). Retention screws received insertion torque and, after 3 minutes, initial detorque was measured. Crowns were retightened and submitted to cyclic loading testing under oblique loading (30 degrees) of 130 +/- 10 N at 2 Hz of frequency, totaling 1 x 10(6) cycles. After cycling, final detorque was measured. Vertical misfit was measured using a stereomicroscope. Data were analyzed by analysis of variance, Tukey test, and Pearson correlation test (P < .05). Results: All detorque values were lower than the insertion torque both before and after mechanical cycling. No statistically significant difference was observed among groups before mechanical cycling. After mechanical cycling, a statistically significantly lower loss of detorque was verified in the MTC group in comparison to the EHC group. Significantly lower vertical misfit values were noted after mechanical cycling but there was no difference among groups. There was no significant correlation between detorque values and vertical misfit. Conclusions: All groups presented a significant decrease of torque before and after mechanical cycling. The morse taper connection promoted the highest torque maintenance. Mechanical cycling reduced the vertical misfit of all groups, although no significant correlation between vertical misfit and torque loss was found.en
dc.description.affiliationUniv Estadual Paulista, UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.format.extent415-422
dc.identifierhttp://dx.doi.org/10.11607/jomi.2727
dc.identifier.citationInternational Journal Of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 28, n. 2, p. 415-422, 2013.
dc.identifier.doi10.11607/jomi.2727
dc.identifier.issn0882-2786
dc.identifier.lattes4438747643373395
dc.identifier.urihttp://hdl.handle.net/11449/112444
dc.identifier.wosWOS:000322077900019
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal of Oral & Maxillofacial Implants
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr1,576
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectfatigue testingen
dc.subjectimplant-supported prosthesesen
dc.subjectmechanical cyclingen
dc.subjectretention screwen
dc.subjecttorqueen
dc.subjectvertical misfiten
dc.titleThe Role of Implant/Abutment System on Torque Maintenance of Retention Screws and Vertical Misfit of Implant-Supported Crowns Before and After Mechanical Cyclingen
dc.typeArtigopt
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4438747643373395
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos