Publicação:
In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments

dc.contributor.authorCastilho, Anderson Almeida [UNESP]
dc.contributor.authorKojima, Alberto Noriyuki [UNESP]
dc.contributor.authorPereira, Sarina Maciel Braga [UNESP]
dc.contributor.authorDe Vasconcellos, Diego Klee [UNESP]
dc.contributor.authorItinoche, Marcos Koiti [UNESP]
dc.contributor.authorFaria, Renata [UNESP]
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:22:28Z
dc.date.available2014-05-27T11:22:28Z
dc.date.issued2007-05-01
dc.description.abstractObjective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Dental School of São José Dos Campos São Paulo State University Júlio de Mesquita Filho, São José dos Campos, SP
dc.description.affiliationJardim Das Colinas, R. P. Jose Maria da Silva Ramos, 250, 12242-250, Sao Jose dos Campos, SP
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Dental School of São José Dos Campos São Paulo State University Júlio de Mesquita Filho, São José dos Campos, SP
dc.format.extent241-246
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572007000300016
dc.identifier.citationJournal of Applied Oral Science, v. 15, n. 3, p. 241-246, 2007.
dc.identifier.doi10.1590/S1678-77572007000300016
dc.identifier.file2-s2.0-34548720857.pdf
dc.identifier.issn1678-7757
dc.identifier.issn1678-7765
dc.identifier.lattes9234456003563666
dc.identifier.scieloS1678-77572007000300016
dc.identifier.scopus2-s2.0-34548720857
dc.identifier.urihttp://hdl.handle.net/11449/69652
dc.identifier.wosWOS:000256794100016
dc.language.isoeng
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectImplant-supported restoration
dc.subjectMolding
dc.subjectStrain gauges
dc.titleIn vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutmentsen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/jaos/iaboutj.htm
dspace.entity.typePublication
unesp.author.lattes9234456003563666
unesp.author.lattes6168075208730450[2]
unesp.author.orcid0000-0003-4607-9095[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-34548720857.pdf
Tamanho:
207.54 KB
Formato:
Adobe Portable Document Format