Logo do repositório

Cervical ventral slot in rabbits (Oryctolagus cuniculus). piezosurgery versus conventional technique

dc.contributor.authorRoscamp, Marcelo [UNESP]
dc.contributor.authorHataka, Alessandre [UNESP]
dc.contributor.authorZambon, Frederico Carlini
dc.contributor.authorFerreira, Danyelle Rayssa Cintra [UNESP]
dc.contributor.authorMinto, Bruno Watanabe [UNESP]
dc.contributor.authorDias, Luis Gustavo Gosuen Gonçalves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionVeterinarian. Anestesia Veterinária Especializada
dc.date.accessioned2022-04-29T08:31:01Z
dc.date.available2022-04-29T08:31:01Z
dc.date.issued2021-01-01
dc.description.abstractPurpose: To investigate the applicability of piezosurgery for cervical ventral slot (CVS), comparing it with the conventional technique of using high-speed burs for bone wear. Methods: Thirty rabbits (Oryctolagus cuniculus) were divided into two treatment groups (T1 and T2) corresponding to CVS between C3-C4. In T1, the surgery was performed with piezoelectric apparatus, and in T2 with high-speed burs. The evaluated parameters were: duration of each stage of surgery, temperature variations during CVS, visibility of the surgical field, intra and postoperative complications, and anesthetic monitoring. At 14, 28, and 56 postoperative days, five animals from each treatment group were submitted for histopathological study of the surgical site. Results: Compared with T2, T1 had more precise bone cut, and better visibility of the operative field, although it required longer total surgical time (p = 0.02) and triggered a greater number of intraoperative complications (p < 0.01), microscopic lesions in the spinal cord (p <0.05), and transient neurological deficits in the postoperatively (p < 0.05). Conclusion: It is necessary to perform surgical planning and have several tips of the piezoelectric instrument available for the safe use of the piezoelectric device in neurosurgery.en
dc.description.affiliationDepartment of Veterinary Medicine and Surgery – College of Agricultural Sciences and Veterinary Medicine Universidade Estadual Paulista “Julio de Mesquita Filho”
dc.description.affiliationDepartment of Veterinary Clinic – College of Veterinary Medicine and Animal Science Universidade Estadual Paulista “Julio de Mesquita Filho”
dc.description.affiliationVeterinarian. Anestesia Veterinária Especializada
dc.description.affiliationUnespDepartment of Veterinary Medicine and Surgery – College of Agricultural Sciences and Veterinary Medicine Universidade Estadual Paulista “Julio de Mesquita Filho”
dc.description.affiliationUnespDepartment of Veterinary Clinic – College of Veterinary Medicine and Animal Science Universidade Estadual Paulista “Julio de Mesquita Filho”
dc.identifierhttp://dx.doi.org/10.1590/ACB360606
dc.identifier.citationActa Cirurgica Brasileira, v. 36, n. 6, 2021.
dc.identifier.doi10.1590/ACB360606
dc.identifier.issn1678-2674
dc.identifier.issn0102-8650
dc.identifier.scopus2-s2.0-85111006166
dc.identifier.urihttp://hdl.handle.net/11449/229194
dc.language.isoeng
dc.relation.ispartofActa Cirurgica Brasileira
dc.sourceScopus
dc.subjectNeurosurgery
dc.subjectPiezosurgery
dc.subjectRabbits
dc.subjectSpinal Cord
dc.titleCervical ventral slot in rabbits (Oryctolagus cuniculus). piezosurgery versus conventional techniqueen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublicationb422a3bf-b05b-47c3-b555-0a5a07e4be78
relation.isDepartmentOfPublication.latestForDiscoveryb422a3bf-b05b-47c3-b555-0a5a07e4be78
relation.isOrgUnitOfPublication9ca5a87b-0c83-43fa-b290-6f8a4202bf99
relation.isOrgUnitOfPublication.latestForDiscovery9ca5a87b-0c83-43fa-b290-6f8a4202bf99
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
unesp.departmentClínica Veterinária - FMVZpt

Arquivos