Effect of abutment's height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis

dc.contributor.authorSuedam, Valdey
dc.contributor.authorSousa, Edson Antonio Capello [UNESP]
dc.contributor.authorMoura, Marcio Silva
dc.contributor.authorJacques, Leticia Borges
dc.contributor.authorRubo, Jose Henrique
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Santa Maria (UFSM)
dc.date.accessioned2014-05-20T13:27:22Z
dc.date.available2014-05-20T13:27:22Z
dc.date.issued2009-02-01
dc.description.abstractIn cantilevered implant-supported complete prosthesis, the abutments' different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis.A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges.Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase.Abutment's height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis.To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment's height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.en
dc.description.affiliationUniv São Paulo, Bauru Sch Dent, Dept Prosthodont, Bauru, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Mech Engn, Fac Engn Bauru, Bauru, SP, Brazil
dc.description.affiliationUniversidade Federal de Santa Maria (UFSM), Dept Restorat Dent, Santa Maria, RS, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Mech Engn, Fac Engn Bauru, Bauru, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 99/01402-6
dc.description.sponsorshipIdFAPESP: 05/56182-3
dc.format.extent196-200
dc.identifierhttp://dx.doi.org/10.1111/j.1600-0501.2008.01609.x
dc.identifier.citationClinical Oral Implants Research. Malden: Wiley-blackwell Publishing, Inc, v. 20, n. 2, p. 196-200, 2009.
dc.identifier.doi10.1111/j.1600-0501.2008.01609.x
dc.identifier.issn0905-7161
dc.identifier.lattes8934648262859482
dc.identifier.urihttp://hdl.handle.net/11449/8970
dc.identifier.wosWOS:000262509500013
dc.language.isoeng
dc.publisherWiley-Blackwell Publishing, Inc
dc.relation.ispartofClinical Oral Implants Research
dc.relation.ispartofjcr4.305
dc.relation.ispartofsjr2,462
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectbiomechanicsen
dc.subjectdental implantsen
dc.subjectmechanical stressen
dc.subjectstrain gaugesen
dc.titleEffect of abutment's height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesisen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell Publishing, Inc
dspace.entity.typePublication
unesp.author.lattes8934648262859482
unesp.author.orcid0000-0003-1595-845X[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.departmentEngenharia Mecânica - FEBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: