Logo do repositório

ProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargement

dc.contributor.authorCastillo Marin, Miguel Christian [UNESP]
dc.contributor.authorAbu Hasna, Amjad [UNESP]
dc.contributor.authorFrozoni, Marcos
dc.contributor.authorDiamantino, Mariana Gadelho Gimenez [UNESP]
dc.contributor.authorRocha, Caroline Trefiglio [UNESP]
dc.contributor.authorValera, Marcia Carneiro [UNESP]
dc.contributor.authorCarvalho, Cláudio Antonio Talge [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidad Espíritu Santo
dc.contributor.institutionSão Leopoldo Mandic School of Dentistry
dc.date.accessioned2025-04-29T18:49:07Z
dc.date.issued2024-10-01
dc.description.abstractBackground/Objectives: This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond. Methods: Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups (n = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student’s t-test, Kruskal–Wallis, and Mann–Whitney test. Results: Significant differences (p < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina. Conclusion: ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.en
dc.description.affiliationDepartment of Restorative Dentistry Endodontics Division Institute of Science and Technology São Paulo State University (ICT-UNESP), São José dos Campos, SP
dc.description.affiliationSchool of Dentistry Universidad Espíritu Santo
dc.description.affiliationDepartment of Endodontics São Leopoldo Mandic School of Dentistry, SP
dc.description.affiliationUnespDepartment of Restorative Dentistry Endodontics Division Institute of Science and Technology São Paulo State University (ICT-UNESP), São José dos Campos, SP
dc.identifierhttp://dx.doi.org/10.3390/dj12100330
dc.identifier.citationDentistry Journal, v. 12, n. 10, 2024.
dc.identifier.doi10.3390/dj12100330
dc.identifier.issn2304-6767
dc.identifier.scopus2-s2.0-85207268890
dc.identifier.urihttps://hdl.handle.net/11449/300257
dc.language.isoeng
dc.relation.ispartofDentistry Journal
dc.sourceScopus
dc.subjectapical foramen
dc.subjectforaminal enlargement
dc.subjectroot canal preparation
dc.titleProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargementen
dc.typeArtigopt
dspace.entity.typePublication
unesp.author.orcid0000-0002-1112-985X[2]
unesp.author.orcid0000-0001-8001-4063[3]
unesp.author.orcid0000-0003-2299-9751[4]
unesp.author.orcid0000-0001-7398-6438[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt

Arquivos