Publicação: Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants with High Incidence of Delayed Graft Function
dc.contributor.author | Tedesco-Silva, Helio | |
dc.contributor.author | Offerni, Juliano Chrystian Mello | |
dc.contributor.author | Carneiro, Vanessa Ayres | |
dc.contributor.author | Paula, Mayara Ivani de | |
dc.contributor.author | David Neto, Elias | |
dc.contributor.author | Lemos, Francine Brambate Carvalhinho | |
dc.contributor.author | Moura, Lúcio Roberto Requião | |
dc.contributor.author | Silva Filho, Alvaro Pacheco e | |
dc.contributor.author | Cunha, Mirian de Fátima de Morais | |
dc.contributor.author | Silva, Erica Francisco da | |
dc.contributor.author | Miorin, Luiz Antonio | |
dc.contributor.author | Demetrio, Daniela Priscila | |
dc.contributor.author | Luconi, Paulo Sérgio | |
dc.contributor.author | Luconi, Waldere Tania da Silva | |
dc.contributor.author | Bobbio, Savina Adriana | |
dc.contributor.author | Kuschnaroff, Liz Milstein | |
dc.contributor.author | Noronha, Irene Lourdes | |
dc.contributor.author | Braga, Sibele Lessa | |
dc.contributor.author | Barsante, Renata Cristina | |
dc.contributor.author | Moreira, João Cezar Mendes | |
dc.contributor.author | Fernandes-Charpiot, Ida Maria Maximina | |
dc.contributor.author | Abbud-Filho, Mario | |
dc.contributor.author | de Andrade, Luis Gustavo Modelli [UNESP] | |
dc.contributor.author | Garcia, Paula Dalsoglio [UNESP] | |
dc.contributor.author | Saber, Luciana Tanajura Santamaria | |
dc.contributor.author | Laurindo, Alan Fernandes | |
dc.contributor.author | Chocair, Pedro Renato | |
dc.contributor.author | Neto, Américo Lourenço Cuvello | |
dc.contributor.author | Zanocco, Juliana Aparecida | |
dc.contributor.author | de Almeida Soares Filho, Antonio Jose Duboc | |
dc.contributor.author | Aguiar, Wilson Ferreira | |
dc.contributor.author | Pestana, Jose Medina | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | |
dc.contributor.institution | Escola Paulista de Medicina | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Hospital Israelita Albert Einstein | |
dc.contributor.institution | Hospital Samaritano | |
dc.contributor.institution | Santa Casa de São Paulo | |
dc.contributor.institution | Hospital Bandeirantes | |
dc.contributor.institution | Hospital do Servidor Público Estadual | |
dc.contributor.institution | Hospital Beneficência Portuguesa | |
dc.contributor.institution | Hospital Dante Pazzanese | |
dc.contributor.institution | Hospital de Base de São José do Rio Preto | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Santa Casa de Ribeirão Preto | |
dc.contributor.institution | Hospital Alemão Oswaldo Cruz | |
dc.contributor.institution | Hospital Santa Marcelina | |
dc.date.accessioned | 2023-03-01T20:42:25Z | |
dc.date.available | 2023-03-01T20:42:25Z | |
dc.date.issued | 2017-05-01 | |
dc.description.abstract | Background. This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). Methods. In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. Results. Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m2 vs 49.0 ± 26.9 mL/min per 1.73 m2; P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m2 vs 54.4 ± 28.6 mL/min per 1.73 m2; P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed. Conclusions. In this cohort of recipients of deceased donor kidneys with high mean cold ischemia time and high incidence of DGF, the use of continuous machine perfusion was associated with a reduced risk of DGF compared with the traditional cold storage preservation method. | en |
dc.description.affiliation | Hospital do Rim Universidade Federal de São Paulo, SP | |
dc.description.affiliation | Organização de Procura de Orgãos Escola Paulista de Medicina, SP | |
dc.description.affiliation | Hospital das Clínicas da Faculdade de Medicina Universidade de São Paulo, SP | |
dc.description.affiliation | Kidney Transplant Unit Hospital Israelita Albert Einstein, SP | |
dc.description.affiliation | Hospital Samaritano, SP | |
dc.description.affiliation | Santa Casa de São Paulo, SP | |
dc.description.affiliation | Hospital Bandeirantes, SP | |
dc.description.affiliation | Hospital do Servidor Público Estadual, SP | |
dc.description.affiliation | Hospital Beneficência Portuguesa, SP | |
dc.description.affiliation | Hospital Dante Pazzanese, SP | |
dc.description.affiliation | Hospital de Base de São José do Rio Preto, SP | |
dc.description.affiliation | Department of Internal Medicine-UNESP Universidade Estadual Paulista, Rubião Jr, S/N, Botucatu | |
dc.description.affiliation | Santa Casa de Ribeirão Preto, SP | |
dc.description.affiliation | Hospital Alemão Oswaldo Cruz, SP | |
dc.description.affiliation | Hospital Santa Marcelina, SP | |
dc.description.affiliation | Nephrology Division Hospital do Rim Universidade Federal de São Paulo, Rua Borges Lagoa, 960-11 Andar | |
dc.description.affiliationUnesp | Department of Internal Medicine-UNESP Universidade Estadual Paulista, Rubião Jr, S/N, Botucatu | |
dc.identifier | http://dx.doi.org/10.1097/TXD.0000000000000672 | |
dc.identifier.citation | Transplantation Direct, v. 3, n. 5, 2017. | |
dc.identifier.doi | 10.1097/TXD.0000000000000672 | |
dc.identifier.issn | 2373-8731 | |
dc.identifier.scopus | 2-s2.0-85130151638 | |
dc.identifier.uri | http://hdl.handle.net/11449/240998 | |
dc.language.iso | eng | |
dc.relation.ispartof | Transplantation Direct | |
dc.source | Scopus | |
dc.title | Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants with High Incidence of Delayed Graft Function | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatu | pt |
unesp.department | Clínica Médica - FMB | pt |