Logotipo do repositório
 

Publicação:
Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants with High Incidence of Delayed Graft Function

dc.contributor.authorTedesco-Silva, Helio
dc.contributor.authorOfferni, Juliano Chrystian Mello
dc.contributor.authorCarneiro, Vanessa Ayres
dc.contributor.authorPaula, Mayara Ivani de
dc.contributor.authorDavid Neto, Elias
dc.contributor.authorLemos, Francine Brambate Carvalhinho
dc.contributor.authorMoura, Lúcio Roberto Requião
dc.contributor.authorSilva Filho, Alvaro Pacheco e
dc.contributor.authorCunha, Mirian de Fátima de Morais
dc.contributor.authorSilva, Erica Francisco da
dc.contributor.authorMiorin, Luiz Antonio
dc.contributor.authorDemetrio, Daniela Priscila
dc.contributor.authorLuconi, Paulo Sérgio
dc.contributor.authorLuconi, Waldere Tania da Silva
dc.contributor.authorBobbio, Savina Adriana
dc.contributor.authorKuschnaroff, Liz Milstein
dc.contributor.authorNoronha, Irene Lourdes
dc.contributor.authorBraga, Sibele Lessa
dc.contributor.authorBarsante, Renata Cristina
dc.contributor.authorMoreira, João Cezar Mendes
dc.contributor.authorFernandes-Charpiot, Ida Maria Maximina
dc.contributor.authorAbbud-Filho, Mario
dc.contributor.authorde Andrade, Luis Gustavo Modelli [UNESP]
dc.contributor.authorGarcia, Paula Dalsoglio [UNESP]
dc.contributor.authorSaber, Luciana Tanajura Santamaria
dc.contributor.authorLaurindo, Alan Fernandes
dc.contributor.authorChocair, Pedro Renato
dc.contributor.authorNeto, Américo Lourenço Cuvello
dc.contributor.authorZanocco, Juliana Aparecida
dc.contributor.authorde Almeida Soares Filho, Antonio Jose Duboc
dc.contributor.authorAguiar, Wilson Ferreira
dc.contributor.authorPestana, Jose Medina
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)
dc.contributor.institutionEscola Paulista de Medicina
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionHospital Israelita Albert Einstein
dc.contributor.institutionHospital Samaritano
dc.contributor.institutionSanta Casa de São Paulo
dc.contributor.institutionHospital Bandeirantes
dc.contributor.institutionHospital do Servidor Público Estadual
dc.contributor.institutionHospital Beneficência Portuguesa
dc.contributor.institutionHospital Dante Pazzanese
dc.contributor.institutionHospital de Base de São José do Rio Preto
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionSanta Casa de Ribeirão Preto
dc.contributor.institutionHospital Alemão Oswaldo Cruz
dc.contributor.institutionHospital Santa Marcelina
dc.date.accessioned2023-03-01T20:42:25Z
dc.date.available2023-03-01T20:42:25Z
dc.date.issued2017-05-01
dc.description.abstractBackground. This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). Methods. In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. Results. Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m2 vs 49.0 ± 26.9 mL/min per 1.73 m2; P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m2 vs 54.4 ± 28.6 mL/min per 1.73 m2; P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed. Conclusions. In this cohort of recipients of deceased donor kidneys with high mean cold ischemia time and high incidence of DGF, the use of continuous machine perfusion was associated with a reduced risk of DGF compared with the traditional cold storage preservation method.en
dc.description.affiliationHospital do Rim Universidade Federal de São Paulo, SP
dc.description.affiliationOrganização de Procura de Orgãos Escola Paulista de Medicina, SP
dc.description.affiliationHospital das Clínicas da Faculdade de Medicina Universidade de São Paulo, SP
dc.description.affiliationKidney Transplant Unit Hospital Israelita Albert Einstein, SP
dc.description.affiliationHospital Samaritano, SP
dc.description.affiliationSanta Casa de São Paulo, SP
dc.description.affiliationHospital Bandeirantes, SP
dc.description.affiliationHospital do Servidor Público Estadual, SP
dc.description.affiliationHospital Beneficência Portuguesa, SP
dc.description.affiliationHospital Dante Pazzanese, SP
dc.description.affiliationHospital de Base de São José do Rio Preto, SP
dc.description.affiliationDepartment of Internal Medicine-UNESP Universidade Estadual Paulista, Rubião Jr, S/N, Botucatu
dc.description.affiliationSanta Casa de Ribeirão Preto, SP
dc.description.affiliationHospital Alemão Oswaldo Cruz, SP
dc.description.affiliationHospital Santa Marcelina, SP
dc.description.affiliationNephrology Division Hospital do Rim Universidade Federal de São Paulo, Rua Borges Lagoa, 960-11 Andar
dc.description.affiliationUnespDepartment of Internal Medicine-UNESP Universidade Estadual Paulista, Rubião Jr, S/N, Botucatu
dc.identifierhttp://dx.doi.org/10.1097/TXD.0000000000000672
dc.identifier.citationTransplantation Direct, v. 3, n. 5, 2017.
dc.identifier.doi10.1097/TXD.0000000000000672
dc.identifier.issn2373-8731
dc.identifier.scopus2-s2.0-85130151638
dc.identifier.urihttp://hdl.handle.net/11449/240998
dc.language.isoeng
dc.relation.ispartofTransplantation Direct
dc.sourceScopus
dc.titleRandomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants with High Incidence of Delayed Graft Functionen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentClínica Médica - FMBpt

Arquivos