Can Clinicians Trust Objective Measures of Hip Muscle Strength From Portable Dynamometers? A Systematic Review With Meta-analysis and Evidence Gap Map of 107 Studies of Reliability and Criterion Validity Using the COSMIN Methodology

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Tipo

Resenha

Direito de acesso

Resumo

t OBJECTIVE: To summarize the evidence on reliability and criterion validity of hip muscle strength testing using portable dynamometers. t DESIGN: Systematic review with meta-analysis. t LITERATURE SEARCH: Five databases were searched from inception to March 2023. t STUDY SELECTION CRITERIA: We included studies investigating reliability or criterion validity of hip flexor, extensor, abductor, adductor, or internal/external rotator strength testing with portable dynamometers in injury-free individuals or those with pelvic/ lower limb musculoskeletal disorders. t DATA SYNTHESIS: We performed meta-analyses for each muscle group, position, and method of fixation. We rated pooled results as sufficient (>75% of studies with correlations ≥0.70), insufficient (>75% of studies with correlations <0.70), or inconsistent (sufficient/insufficient results). We assessed the quality of evidence, created evidence gap maps, and made clinical recommendations. t RESULTS: We included a total of 107 studies (reliability 103, validity 14). The intrarater and interrater reliability for hip muscle strength testing across different positions and methods of fixation was sufficient (intraclass correlation coefficient = 0.78-0.96) with low- to high-quality evidence. Criterion validity was less investigated and mostly inconsistent (very low–to moderate-quality evidence) with a wide range of correlations (r = 0.40-0.93). t CONCLUSION: Hip muscle strength testing using portable dynamometers is reliable. The use of portable dynamometers as clinical surrogates for measuring strength using an isokinetic dynamometer requires further investigation. Clinicians testing hip muscle strength with portable dynamometers should use external fixation seated for hip flexors, prone or supine for hip extensors, side-lying or supine for abductors and adductors, and prone and seated for internal and external rotators.

Descrição

Palavras-chave

agreement, dynamometry, force, hip muscle function, isometric strength, measurement properties

Idioma

Inglês

Citação

Journal of Orthopaedic and Sports Physical Therapy, v. 53, n. 11, p. 655-672, 2023.

Itens relacionados

Financiadores

Unidades

Item type:Unidade,
Faculdade de Ciências e Tecnologia
FCT
Campus: Presidente Prudente


Departamentos

Cursos de graduação

Programas de pós-graduação

Outras formas de acesso