Logotipo do repositório
 

Publicação:
An investigation into the effects of resonances on the time delay estimate for leak detection in buried plastic water distribution pipes

dc.contributor.authorAlmeida, Fabricio C. L. [UNESP]
dc.contributor.authorBrennan, Michael J. [UNESP]
dc.contributor.authorJoseph, Phillip F.
dc.contributor.authorDray, Simon
dc.contributor.authorWitfield, Stuart
dc.contributor.authorPaschoalini, Amarildo T. [UNESP]
dc.contributor.authorCunha, A.
dc.contributor.authorCaetano, E.
dc.contributor.authorRibeiro, P.
dc.contributor.authorMuller, G.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionInstitute of Sound and Vibration Research (ISVR)
dc.contributor.institutionUniversity of Southampton
dc.contributor.institutionHydrosave Ltd
dc.contributor.institutionSouth Staffs Water plc
dc.date.accessioned2015-11-03T15:30:23Z
dc.date.available2015-11-03T15:30:23Z
dc.date.issued2014-01-01
dc.description.abstractIn water distribution systems, old metallic pipes have been replaced by plastic pipes due to their deterioration over time. Although acoustic methods are effective in finding leaks in metallic pipes, they have been found to be problematic when applied to plastic pipes due to the high damping within the pipe wall and the surrounding medium. This is responsible for the leak signal not traveling long distances. Moreover, the leak energy in plastic pipes is generally located at a narrow frequency range located at low frequencies. However, the presence of resonances can narrow even more this frequency range. In order to minimise the influence of background noise and resonances on the calculation of the time delay estimate, band-pass filters are often used to supress undesirable frequency components of the noise. The objective of this paper is to investigate the influence of resonances in the pipe system (pipe, valves, connections and hydrants), on the time delay estimate calculated using acoustic signals. Analytical models and actual leak data collected in a bespoke rig located in the United Kingdom are used to investigate this feature.en
dc.description.affiliationInstitute of Sound and Vibration Research (ISVR), Faculty of Engineering and the Environment, University of Southampton, University Road, SO17 1BJ, Southampton, United Kingdom
dc.description.affiliationHydrosave Ltd, Swallow Court, Venture Park, Kettering NN15 6XX, United Kingdom
dc.description.affiliationSouth Staffs Water plc, Green Lane, Walsall WS2 7PD, United Kingdom.
dc.description.affiliationUnespDepartment of Mechanical Eng., State University of São Paulo (UNESP), Ilha Solteira Campus, Av. Brasil.
dc.format.extent3129-3136
dc.identifierhttp://paginas.fe.up.pt/~eurodyn2014/CD/program.html
dc.identifier.citationEurodyn 2014: Ix International Conference On Structural Dynamics. Munich: European Assoc Structural Dynamics, p. 3129-3136, 2014.
dc.identifier.issn2311-9020
dc.identifier.urihttp://hdl.handle.net/11449/130222
dc.identifier.wosWOS:000354786604022
dc.language.isoeng
dc.publisherEuropean Assoc Structural Dynamics
dc.relation.isnodouble176017*
dc.relation.ispartofEurodyn 2014: Ix International Conference On Structural Dynamics
dc.relation.ispartofsjr0,165
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectLeak detectionen
dc.subjectPlastic pipesen
dc.subjectResonancesen
dc.titleAn investigation into the effects of resonances on the time delay estimate for leak detection in buried plastic water distribution pipesen
dc.typeTrabalho apresentado em evento
dcterms.rightsHolderEuropean Assoc Structural Dynamics
dspace.entity.typePublication
unesp.author.lattes8272223904033177[6]
unesp.author.orcid0000-0003-1887-2678[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Mecânica - FEISpt

Arquivos