Logotipo do repositório
 

Publicação:
The Influence of Pit and Fissure Sealants on Infrared Fluorescence Measurements

dc.contributor.authorDiniz, M. B. [UNESP]
dc.contributor.authorRodrigues, J. A. [UNESP]
dc.contributor.authorHug, I.
dc.contributor.authorCordeiro, Rita de Cássia Loiola [UNESP]
dc.contributor.authorLussi, A.
dc.contributor.institutionUniv Bern
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:22Z
dc.date.accessioned2014-05-20T13:44:53Z
dc.date.available2013-09-30T18:31:22Z
dc.date.available2014-05-20T13:44:53Z
dc.date.issued2008-01-01
dc.description.abstractThe aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device. Copyright (C) 2008 S. Karger AG, Basel.en
dc.description.affiliationUniv Bern, Sch Dent Med, Dept Prevent Restorat & Pediat Dent, Bern, Switzerland
dc.description.affiliationSão Paulo State Univ, Sch Dent Araraquara, Dept Pediat Dent, Araraquara, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Sch Dent Araraquara, Dept Pediat Dent, Araraquara, Brazil
dc.format.extent328-333
dc.identifierhttp://dx.doi.org/10.1159/000151327
dc.identifier.citationCaries Research. Basel: Karger, v. 42, n. 5, p. 328-333, 2008.
dc.identifier.doi10.1159/000151327
dc.identifier.issn0008-4166
dc.identifier.lattes8185082796673527
dc.identifier.urihttp://hdl.handle.net/11449/15748
dc.identifier.wosWOS:000259892400002
dc.language.isoeng
dc.publisherKarger
dc.relation.ispartofCaries Research
dc.relation.ispartofjcr1.243
dc.relation.ispartofsjr0,579
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectDental caries, diagnosisen
dc.subjectLaser fluorescenceen
dc.subjectPit and fissure sealantsen
dc.titleThe Influence of Pit and Fissure Sealants on Infrared Fluorescence Measurementsen
dc.typeArtigo
dcterms.licensehttp://www.karger.com/Journal/Guidelines/238704#15
dcterms.rightsHolderKarger
dspace.entity.typePublication
unesp.author.lattes8185082796673527
unesp.author.orcid0000-0001-8887-2329[2]
unesp.author.orcid0000-0002-0693-2162[1]
unesp.author.orcid0000-0002-5644-2807[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: