Logotipo do repositório
 

Publicação:
Step by step analyses of Clarke's matrix correction procedure for untransposed three-phase transmission line cases

dc.contributor.authorDo Prado, Afonso José [UNESP]
dc.contributor.authorKurokawa, Sérgio [UNESP]
dc.contributor.authorPissolato Filho, José
dc.contributor.authorBovolato, Luiz Fernando [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2022-04-28T21:37:12Z
dc.date.available2022-04-28T21:37:12Z
dc.date.issued2010-12-06
dc.description.abstractThe correction procedure for Clarke's matrix, considering three-phase transmission line analyzes, is analyzed step by step in this paper, searching to improve the application of this procedure. Changing the eigenvectors as modal transformation matrices, Clarke's matrix has been applied to analyses for transposed and untransposed three-phase transmission line cases. It is based on the fact that Clarke's matrix is an eigenvector matrix for transposed three-phase transmission lines considering symmetrical and asymmetrical cases. Because of this, the application of this matrix has been analyzed considering untransposed three-phase transmission lines. In most of these cases, the errors related to the eigenvalues can be considered negligible. It is not true when it is analyzed the elements that are not in main diagonal of the quasi-mode matrix. This matrix is obtained from the application of Clarke's matrix. The quasi-mode matrix is correspondent to the eigenvalue matrix. Their off-diagonal elements represent couplings among the quasi-modes. So, the off-diagonal quasi-mode element relative values are not negligible when compared to the eigenvalues that correspond to the coupled quasi-modes. Minimizing these relative values, the correction procedure is analyzed in detail, checking some alternatives for the correction procedure application. ©2010 IEEE.en
dc.description.affiliationDepartment of Electrical Engineering FEIS/UNESP - The University of São Paulo State
dc.description.affiliationDepartment of Electrical Engineering DSCE/UNICAMP - The State University of Campinas
dc.description.affiliationUnespDepartment of Electrical Engineering FEIS/UNESP - The University of São Paulo State
dc.identifierhttp://dx.doi.org/10.1109/PES.2010.5589922
dc.identifier.citationIEEE PES General Meeting, PES 2010.
dc.identifier.doi10.1109/PES.2010.5589922
dc.identifier.scopus2-s2.0-78649584836
dc.identifier.urihttp://hdl.handle.net/11449/226143
dc.language.isoeng
dc.relation.ispartofIEEE PES General Meeting, PES 2010
dc.sourceScopus
dc.subjectClarke's matrix
dc.subjectEigenvalue
dc.subjectEigenvector
dc.subjectError analysis
dc.subjectFrequency dependent parameters
dc.subjectNon symmetrical lines
dc.subjectPhase mode transformation
dc.titleStep by step analyses of Clarke's matrix correction procedure for untransposed three-phase transmission line casesen
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos