Logotipo do repositório
 

Publicação:
Evaluation of the microvascular density in astrocytomas in adults correlated using SPECT-MIBI

dc.contributor.authorCavalcante, Sandro Pantoja [UNESP]
dc.contributor.authorWalther de Almeida, Jose Reynaldo
dc.contributor.authorClara, Carlos Afonso
dc.contributor.authorScapulatempo Neto, Cristovam
dc.contributor.authorPeres, Stela Verzinhase
dc.contributor.authorMoriguchi, Sônia Marta [UNESP]
dc.contributor.authorDos Santos, Marcelo Jose
dc.contributor.authorDa Rocha, Euclides Timoteo [UNESP]
dc.contributor.institutionHosp Canc Fundação Pio XII
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:32:58Z
dc.date.available2014-05-20T15:32:58Z
dc.date.issued2010-03-01
dc.description.abstractMicrovascular density (MVD) may be an additional prognostic marker for astrocytomas, but the heterogeneity of these tumors limits its use. Thus, imaging examinations such as SPECT-MIBI (2-methoxyisobutyl isonitrile) may take on an indirect role in astrocytoma evaluation. The aim of this study was to evaluate MVD in astrocytomas using immunohistochemistry with anti-CD34 monoclonal antibodies. The relationship between the immunohistochemical data and the parameters obtained from SPECT-MIBI was evaluated. This cross-sectional study evaluated 48 patients with brain tumors including low-grade astrocytomas (LGAs), anaplastic astrocytomas (AAs) and glioblastoma multiformes (GBMs). Patients had been admitted to the Hospital de Cancer de Barretos - Fundação Pio XII, and underwent brain SPECT-MIBI prior to any treatment. MVD was determined under an optical microscope by counting microvessels on slides from each case. SPECT-MIBI images were analyzed visually and semiquantitatively. GBMs, AAs and LGAs represented 50, 16.7 and 33.3% of the total sample, respectively. There were 13 normal and 35 abnormal SPECT-MIBI images. Significant differences in MVD were found between AA and LGA cases (p=0.040), but not between normal and abnormal SPECT-MIBI. The mean counts from SPECT-MIBI were not correlated with MVD. Among the GBM cases, there were no significant findings, except for an increased likelihood of abnormal histological test results. MVD was related to histological grade (in AA and LGA cases) but was not correlated with SPECT-MIBI.en
dc.description.affiliationHosp Canc Fundação Pio XII, Dept Surg, Neurooncol Div, BR-14784400 Barretos, Brazil
dc.description.affiliationHosp Canc Fundação Pio XII, Dept Pathol, BR-14784400 Barretos, Brazil
dc.description.affiliationHosp Canc Fundação Pio XII, Res Support Grp, BR-14784400 Barretos, Brazil
dc.description.affiliationSão Paulo State Univ UNESP, Sch Med, Ctr Blood Transfus, BR-18618000 São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Sch Med, Ctr Blood Transfus, BR-18618000 São Paulo, Brazil
dc.format.extent293-299
dc.identifierhttp://dx.doi.org/10.3892/etm_00000045
dc.identifier.citationExperimental and Therapeutic Medicine. Athens: Spandidos Publ Ltd, v. 1, n. 2, p. 293-299, 2010.
dc.identifier.doi10.3892/etm_00000045
dc.identifier.issn1792-0981
dc.identifier.urihttp://hdl.handle.net/11449/41732
dc.identifier.wosWOS:000284811700010
dc.language.isoeng
dc.publisherSpandidos Publ Ltd
dc.relation.ispartofExperimental and Therapeutic Medicine
dc.relation.ispartofjcr1.410
dc.relation.ispartofsjr0,510
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectmicrovascular densityen
dc.subjectSPECT-MIBIen
dc.subjectastrocytomasen
dc.titleEvaluation of the microvascular density in astrocytomas in adults correlated using SPECT-MIBIen
dc.typeArtigo
dcterms.licensehttp://www.spandidos-publications.com/pages/terms
dcterms.rightsHolderSpandidos Publ Ltd
dspace.entity.typePublication
unesp.author.orcid0000-0001-5834-2714[6]
unesp.author.orcid0000-0002-8920-6579[4]
unesp.author.orcid0000-0001-5834-2714[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentDoenças Tropicais e Diagnósticos por Imagem - FMBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: