Logotipo do repositório
 

Publicação:
Effect of Cement Type, Relining Procedure, and Length of Cementation on Pull-out Bond Strength of Fiber Posts

dc.contributor.authorMacedo, Vanessa Cruz [UNESP]
dc.contributor.authorFaria e Silva, Andre Luis
dc.contributor.authorMarcondes Martins, Luis Roberto
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Sergipe (UFS)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2014-05-20T14:05:00Z
dc.date.available2014-05-20T14:05:00Z
dc.date.issued2010-09-01
dc.description.abstractIntroduction: As opposed to the cementation metal posts, the cementation of fiber posts has several details that can significantly influence the success of post retention. This study evaluated the effect of the relining procedure, the cement type, and the luted length of the post on fiber posts retention. Methods: One hundred eighty bovine incisors were selected to assess post retention; after endodontic treatment, the canals were flared with diamonds burs. Post holes were prepared in lengths of 5, 7.5, and 10 mm; the fiber posts were relined with composite resin and luted with RelyX ARC, RelyX Unicem, or RelyX Luting 2. All cements are manufactured by 3M ESPE (St. Paul, MN). Samples were subjected to a pull-out bond strength test in a universal testing machine; the results (N) were submitted to a three-way analysis of variance and the Tukey post hoc test (alpha = 0.05). Results: The improvement of post retention occurred with the increase of the post length luted into the root canal; the relining procedure improved the pull-out bond strength. RelyX Unicem and RelyX ARC showed similar values of retention, both showing higher values than RelyX Luting 2. Conclusion: Post length, the reining procedure, and the cement type are all important factors for improving the retention of fiber posts. (J Endod 2010;36:1543-1546)en
dc.description.affiliationSão Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUniv Fed Sergipe, Dept Dent, Aracaju, SE, Brazil
dc.description.affiliationUniv Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP, Brazil
dc.format.extent1543-1546
dc.identifierhttp://dx.doi.org/10.1016/j.joen.2010.04.014
dc.identifier.citationJournal of Endodontics. New York: Elsevier B.V., v. 36, n. 9, p. 1543-1546, 2010.
dc.identifier.doi10.1016/j.joen.2010.04.014
dc.identifier.issn0099-2399
dc.identifier.urihttp://hdl.handle.net/11449/22792
dc.identifier.wosWOS:000281657100019
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Endodontics
dc.relation.ispartofjcr2.886
dc.relation.ispartofsjr1,585
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectBond strengthen
dc.subjectfiber posten
dc.subjectresin cementen
dc.titleEffect of Cement Type, Relining Procedure, and Length of Cementation on Pull-out Bond Strength of Fiber Postsen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: